48 56 58.5 Q 46 50 52 52 R 36 44 53 55.5 Q 63 66 69 69 R 35 42 51 53.5 Q 27 30 32 32 VCA21 VCA31 41 50 60 68 18 24 30 35 64 76 86 91 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 17-2-13 8 Series VCA How to Order Manifold (VCA20) How to Order Manifold Assembly VV2C A 2 02 02 Enter the mounting valve and option part numbers
(mg/L) 200 50 50 (mg/L) 200 50 50 [pH4.8](mgCaCO3/L) 100 50 50 (mgCaCO3/L) 200 70 70 (mgCaCO3/L) 150 50 50 (mgSiO2/L) 50 30 30 (mg/L) 1.0 0.3 1.0 (mg/L) 0.3 0.1 1.0 (mg/L) (mg/L) 1.0 0.1 1.0 (mg/L) 0.3 0.3 0.3 (mg/L) 4.0 4.0 4.0 6.07.0 1 2 JIS K 0101 2 a b c 4.2 IDF100150F-W 4 2 IDX-OM-Z004 4 (3) 1 Y Y , Y Y (4) 3 2 (5) 1( 2 3 4 a) 1. 1.5
rate: 50% Stroke 300 mm 6 10 16 20 25 32 40 Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ3140-M5 Cylinder is in extending.
ZX 36 A VJ10 ZR Rated voltage Lead wire length ZM (Mounting hole) Symbol L (mm) Symbol Rated voltage Lead wire color Nil 6 10 15 20 25 30 1 300 100 VAC 50/60 Hz 110 VAC 50/60 Hz (115 VAC 60 Hz) Blue (2 pcs.)
Ball screw allowable rotation X axis specifications in-line mount (side mount) 200 20 40 W mm Motor Ball screw lead Guide Maximum work load Maximum speed Repeatability 400 750 20 40 4000 Allowable rotation rpm 20 40 3000 High rigidity direct acting guide 2000 kg mm/s mm 30 1000 15 2000 50 1000 25 2000 100(75) 1000 50(37.5) 2000 1000 0.05 (897) 1) When axes are combined, select each axis considering
A quick recovery time indicates little liquid pool. 50 Ratio of resistance [k m] Particle ratio [number/cc] PFMC 100 2 or 3 particles/cc PFMV 10 00 10 20 30 40 50 60 70 PF2A 1 0 5 10 15 20 25 30 Duration of flow [min] Duration of flow [hour] PF3W The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room
100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel distance [mm] Total travel distance [mm] 36 - (2) Speed entry method Settings: Target position [mm], Speed [mm/s], Acceleration [mm/s2], Deceleration [mm/s2], Load mass [g] To obtain the total travel distance S [mm] in absolute Acceleration Aa Speed Vc Speed [mm/s] positioning
3.5 8 14 KQU08-U02 17 15.2 52 15.2 46 18.5 25.6 1/4 1/8 KQU07-U01 14.29 13.2 44.5 13.2 40.5 17 4.6 8 38 KQU08-U03 17 15.2 51.5 15.2 45.5 18.5 25.6 1/4 1/4 KQU07-U02 14.29 13.2 46 13.2 40 17 4.6 10 14 KQU10-U02 19 18.5 57.5 18.5 51.5 21 40 1/4 3/8 KQU07-U03 17.46 13.2 46.5 13.2 40.5 17 4.6 10 38 KQU10-U03 19 18.5 57.5 18.5 51.5 21 40 5/16 1/8 KQU09-U03 17.46 15.2 50.5 15.2 46.5 18.5 6 10
50 60 70 Circulating fluid temperature [C] 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] For the high-pressure pump (Option), the cooling capacity decreases by approx. 20 W.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2
5% ON OFF [F 2] OUT2 34 () ( ) ON OFF 50% 5% OUT1 -23No.PF-OMN0011CN-C [F 3] 40 1 [F10] 41 [F20] 45 [F22] 46 OFF [F30] 48 OFF [F80] 49 () [F81] 50 OFF [F82] 51 [*] [F90] 52 OFF [F96] 53 () [F97] 54 OFF [F98] 57 OFF [F99] 58 OFF 30 [F10](41 ) (4 L/min ) OUT1 OUT1 OFF OUT2 -24No.PF-OMN0011CN-C [F 0] 2 [F 0] [RANGE] [F 0] -25No.PF-OMN0011CN-C [F
95 + Stroke 40 + Stroke 0.05 24.8 40 0.1 25 View A-A 50 100 (119.3) 11 0.1 11 0.1 30 0.03 4 surfaces 2 x 9 4 surfaces 2 x 6 F7 11 0.1 11 0.1 40 0.05 45 10 15 Coil scraper 68.5 55 127 + Stroke 45 0.03 95 9.5 26.5 A A 11 30 M12 connector (4 pin) 109 Protective plate 132.5 2 x 8 F7 depth 16 90 9.5 13.5 10.5 4 x M10 depth 16 (Helisert) 45 G, NPT1/4 (Max. 69) 10 5 CKZP71-m Rod extended 16.1 80
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Orifice dia.
ST 10 20 30 40 50 9+ST 19 29 39 49 59 10+ST 20 30 40 50 60 37+ST 47 57 67 77 87 47+ST 57 67 77 87 97 CXSJ6-10 21-/2211-/12CXSJ6-20 CXSJ6-30 CXSJ6-40 CXSJ6-50 21-/2211-/1221-/2211-/1221-/2211-/1221-/2211-/12850 Dual Rod Cylinder/Compact Type CXSJ 2122CXSJ/ 1112Dimensions: 10 16 17+ST 4 x M3 x 0.5 thread depth 4.5 3.5 8 7.5 2 x M5 x 0.8 thread depth 4 (Piping port) 21 8 Steel ball 34 M3 x 0.5
Table 1 Tightening torque ( Unit: Nm ) Foot Flange Plug bolt Cushion valve Cushion valve (Lock nut) Bore size (mm) (Valve retainer) 20 1.5 2.0 0.5 25 2.9 2.0 0.5 32 2.9 2.0 0.5 40 4.9 2.0 0.5 50 11.8 5.0 1.0 63 24.5 5.0 1.0 80 24.5 20.0 2.0 100 42.2 20.0 2.0 6.
36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2 25 4 x M8 x 1.25 Effective thread
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
Ensure the piping cools sufficiently before touching. 50% of maximum rated flow [ 50] 50 oC (for all ranges) [ tn_2] Set value (OUT2) Pin number of the connector (On the lead wire) 90o End stop position 0% of maximum rated flow [ 5] 5 oC (for all ranges) [ tH_2] Hysteresis (OUT2) After maintenance is complete, perform appropriate functional inspections and leak tests.
The data set by auto preset function is fine turned. 16-2-40 17 Series ZSE 50 60F/ISE 50 60 High Precision, Digital Pressure Switch for General Fluids Setting (Common to ZSE50F/ISE50 and ZSE60F/ISE60) Initial setting 1. Initial setting mode 2. OUT1 output mode selection 3. OUT2 output mode selection SET ZSE ISE Press the SET button. PSE Press the SET button at least 2 seconds.
According to d = 40, E2 is obtained. Weight equivalent to impact object Me (kg) 0.628 1.10 1.26 1.34 2.04 5.