SMC Corporation of America
Elite Part Number Search
Search Results "RZQL50-100-50"

Bore size Stroke range head cap screw for CW CT CL CX CD M CZ R CN mounting pivot bracket (Accessory) Without auto switch With auto switch CQ-C032 32 5 to 50 50 60 60 20 5 30 18 10 34 45 80 6.6 M6 x 12 L 75, 100 5 to 50 58.5 68.5 66.5 76.5 CQ-C040 40 68.5 22 6 32 18 10 40 52 80 6.6 M6 x 14 L 75, 100 10 to 50 CQ-C050 50 76.5 28 7 42 22 14 50 64 80 9 M8 x 16 L 75, 100 CQ2 10 to 50 74 84 CQ-C063

The guideline is 80% or less. 0 to 100 % 7 Effective load ratio The continuous effective load torque is displayed. The effective value is displayed relative to the rated torque of 100%. 0 to 300 % 8 Peak load ratio The maximum torque is displayed.

Horizontal and lateral Mounting Vertical Mounting 50 RS H A 2.

Horizontal and lateral Mounting Vertical Mounting 50 RS H A 2.

/60HZ ) For 100V Single phase 100 to 115VAC (50/60HZ ) R T 1MCCB Equipment Connection Example Noise filter External noise is prevented by the noise filter.

S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

0.1 0.1 5 L L 0 20 30 50 60 Holding point L (mm) 40 70 0 30 40 60 70 Holding point L (mm) 50 80 90 2.8-4 180 Angular Gripper Series MHY2/MHW2 MHW2-32D MHW2-50D MHW2-20D 300 25 100 Pressure 0.7MPa Pressure 0.7MPa Pressure 0.7MPa 250 20 0.6 80 0.6 0.6 Holding force (N) Holding force (N) Holding force (N) 200 0.5 0.5 0.5 60 15 0.4 0.3 150 0.4 0.4 40 10 0.3 0.3 100 0.2 0.2 0.2 5 20 50 0 0 40

To move the actuator of which lead is 10mm for 100mm: move distance[pulse] 100(mm) / actuators move distance per pulse[mm/pls] 100(mm) / ( 10(mm) / 262144(pulse) ) 2621440(pulse) * Ensure that the [Forward (CCW)] and [Reverse (CW)] driving directions are checked.

Height: 30 mm (LOW type), 100 mm (HIGH type) W H L2 T L1 [mm] Model C(L)KQG32 Compact cylinder type (Guide pin diameter: 12) C(L)KU32 Plate cylinder type (Guide pin diameter: 12) C(L)KQG50 (Guide pin diameter: 13) Clamping height LOW type HIGH type LOW type HIGH type LOW type HIGH type Clamping height H 30 100 30 100 24 54 Body thickness T 50 29 66 Body width W 50 70 66 Body length L1 127

1 0 lo 1 00 Double rcd o12,o16/5llj30 o20 to o40l5 to 50 o50, 06311 0 to 50 Standaid Double acting Slngle rcd o12. 01615 to 30 o2Oa /5lo50 o32. s4015 lo lOO o50 to o 100/10 to 100 Double rod o i 2 , o 1 6 1 5 t o 3 0 a2O, o25l5Io 50 a32,64015lo lOO o50 to 010C/10to 100 Singleacting Sp ng retum/extend o 1 2 I o s 4 \ l 5 , 1 Q aslt1O.20 @eooy options @Auto switcn See catal N320 for avaibble

PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes

0.04 0.08 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.04 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.03 0.06 0.03 0.04 0.02 0.02 0.01 0.02 0.01 0 50 100 150 Load (N) 0 50 100 150 Load (N) 0 50 100 150 Load (N) 200 16 16 16 L=120mm L=120mm L=120mm MXP16-20 MXP16-30 MXP16-20 MXP16-30 0.08 0.12 0.06 MXP16-20 MXP16-30 MXP16-20 MXP16-30 MXP16

W Fulcrum L Front matter 5 Series CKZ3 Model Selection Model Selection CKZ3N North American Type Made to Order European Type CKZ3T 3 Clamp arm 50 63 300 150 280 140 Distance from pivot point L(mm) Distance from pivot point L(mm) 260 130 240 120 220 110 200 100 180 90 160 80 140 70 120 60 100 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 50 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

The chart on the left illustrates the example when 100 [kPa], F.S. = 100 0 = 100 [kPa], 3.0% F.S. = 100 x 0.03 = 3 [kPa]. It means that if the tempareture is changed within the range of 0 to 50[C], the error will occur at the max. 3 [kPa].

Table 7-1 Quality criteria for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

mA Residual voltage: 1 V or less (Load current: 100 mA) Maximum applied voltage: 26.4 VDC Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Maximum applied voltage: 26.4 VDC Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Error signal Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Output

Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire

With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN

dimensions 055 55 x t20 100 200 100 x t30 200 x 140 x t40 Magnetic separator Magnetic separator Fluid Iron Content Elimination Performance by Iron Particle Concentration FHMN-055 FHM-100 FHM-200 Fluid: Hydraulic fluid Fluid: Hydraulic fluid Fluid: Hydraulic fluid 100 90 80 70 60 50 40 30 20 10 0 1 5 10 50 100 100 90 80 100 90 80 70 60 50 40 30 20 10 0 100 200 300 400 500 100 200 300 400 500

VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual override 7 7 Non-locking push type Non-locking push type A (projecting) Nil Semi-standard For other rated voltages