SMC Corporation of America
Elite Part Number Search
Search Results "S070C-VDC-32"

, variable from 0 to 60 s/0.01 s increments Hysteresis Variable from 04 Protection Over current protection Input type Voltage input: 1 to 5 VDC (Input impedance: 1 M) Number of inputs 4 inputs Connection method e-CON Protection Over voltage protection (up to a voltage of 26.4 VDC) Auto-shift input5 Voltage free input (Reed or Solid state), input for 5 ms or longer, Independently controllable

24 VDC +10%/-10% Under-voltage detection approx. 18 VDC PWR(V) Operating voltage 24 VDC +10%/-5% Galvanic isolation Yes (between PWR and PWR(V)) Fieldbus Bus protocol PROFINET I/O Version PROFINET Specification Version 2.3 Conformance Class C Yes (Only for IRT switch function) FSU (Fast Start Up) Yes MRP (Media Redundancy Protocol) Yes MRPD (Media Redundancy for Planned Duplication) Yes

VK300-82-2-01 100 VAC V100 VK300-82-2-03 110V 110 VAC 200 VAC 220 VAC VK300-82-2-02 200V VK300-82-2-04 220V S070 240V 6V 12V 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal VQD VQD-V Light (Built-in connector) Marking Circuit with light AC Circuit diagram 12 VDC or less Circuit diagram 24 VDC or more Circuit

Grommet: VKF334-G-01 DIN terminal: VKF334-D-01 Base mounted type 33.5 16.7 26 4 Manual override (non-locking) A 12.7 20 10 18.5 20.5 3 32 71.5 Max. 10 2-4.3 (mounting holes) Applicable cord O.D. 4 to 6.5 48.5 Approx. 300 (lead wire length) 26 4 Pg.7 3 27 Manual override (non-locking) A 20.5 18.5 3 32 59 68 78 70.5 43.5 12 7.5 P R 13.5 11 33.5 7.5 12 43.5 P R 3-Rc(PT) 1/8 (ports P, A, R) 13.5

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal

(Symbol 1) IN (Symbol 2) OUT Nil 300 mm 600 mm 1000 mm For the LVM11, the type with power-saving circuit is standard. 6 10 Coil voltage 10R4 N.O. 2 Option (Symbol 3) IN (Symbol 2) OUT Symbol Voltage Nil None Bracket Manual override Bracket, Manual override 5 6 24 VDC 12 VDC 1 2 3 10R6 N.C.

10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.

100/150 Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal HRSH 090 HRSH To the thermo-chiller Users equipment side HRSE 7 24 VDC 6 24 VDC output (500 mA MAX) 5 HRZ 15 14 HRZD 24 VCOM output 13 24 VCOM HRW Signal description Default

30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/

kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting

Electric Slide Table/Compact Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LES8, 16, 25 Series LES RoHS How to Order S 1 1 R J 6N LES 8 30 q w e r t y u i o !0 !1 !2 !

Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input

E2E-X2D1-N Model Output type Normally open Power supply voltage (Operating voltage range) 12 to 24 VDC (10 to 30 VDC) Ripple 10% or less (P-P) Current consumption (Leakage current) 0.8 mA or less Response frequency 1.5 kHz Control output (Chest) 3 to 100 mA Operation indication (Red LED), Set operation indication (Green LED) Indicator LED RSQ Ambient temperature 25 to 70C (No freezing) Operating

(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Incorrect power supply Supply the correct voltage of 12 to 24 VDC 10%. Check the wiring to the power supply.