RS-232C OUT1 to OUT 5 OUT1 to OUT20 (Bank switching) Binary output (31 points) RB J D-X 20Data 10-12-27 Series CEU5 Multi-counter/Specifications CEU5 CEU5-D CEU5P CEU5P-D CEU5B CEU5B-D CEU5PB CEU5PB-D Model Type Multi-counter Mounting Surface mounting (DIN rail or Screw stop) Operating system Adding subtracting type Operation mode Operating mode, Data setting mode, Function setting mode
Applicable Auto Switch Model Reed Switch Solid State Switch D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3lA/A44A D-A3lC/A44C D-A7/A8 D-A7lH/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9/A9lV D-9/9lA D-E7lA/E80A D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7lF D-H7lW D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5lW/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7lF D-F7BAL D-F7lV D-F7NTL D-F7lW(V) D-F5/J5 D-F5BAL D-F5lW
Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A5/A6 D-F5(W)/J59(W)/F5BA D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-Z7/Z80 Hs Hs A A Ht Ht Ht Ht B B Auto Switch Mounting Height Auto Switch Proper Mounting Position D-F5/J59 D-F5W/J59W D-F59F D-F5BA D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-A59W D-F5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-M9V/M9WV D-M9A V D-A5/A6
IOL_Autostart DI_C/Q Digital input only. DO_C/Q Digital output only. -23No.EX-OMY0026 IO-Link master unit parameters (continued) No.
Note 2) The seal is for 40 m and 80 m elements. 784 Vacuum Filter AFJ20 to AFJ40 Series Dimensions AFJ20 N T J M D U Bracket (Option) S SP R ZCUK C B V Q IN OUT AMJ AFJ AFJ 2 x P (Port size) AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 707 Series ARP20/30/40 Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 765 ARP20/30/40 Series Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
d D D C C H B H B B C D d H B C D d H Part no.
Type Applicable cylinder series Auto switch model Applicable magnetic field Electrical entry Wiring (Pin no. in use) Lead wire length Applicable load Indicator light Load voltage D-P3DWASC D-P3DWASE D-P3DWA D-P3DWAL D-P3DWAZ D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ D-P79WSE D-P74L D-P74Z 2-wire (34) Pre-wired connector 0.3 m 2-wire (14) 0.5 m AC magnetic field (Single-phase AC welding magnetic field
D-DN This catalog is printed on recycled paper with concern for the global environment.
Hs A B A B Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-F7WV D-J79C D-A79W D-A7 D-A80 Bore size (mm) D-A7/A80 D-A79W Bore size (mm) Hs Hs Hs Hs Hs Hs 20 B A B A B A A B 25 20 32 34 35 38 32.5 38.5
Hs A B A B Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-F7WV D-J79C D-A79W D-A7 D-A80 Bore size (mm) D-A7/A80 D-A79W Bore size (mm) Hs Hs Hs Hs Hs Hs 20 B A B A B A A B 25 20 32 34 35 38 32.5 38.5
30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the
D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Auto switch part no.
Proper Mounting Position (Detection at Stroke End) and Mounting Height 32, 40, 50, 63 D-M9/D-M9W/D-A9 D-M9V/D-M9WV/D-A9V Hs B W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6)
(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.
(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.
(Same surface) Hs 22 B A D-A93 24.5 10.5 16.5 50 50 50 D-M9B D-M9BW D-B54 50 50 75 Auto Switch Mounting Position and Its Height Unit: mm 8.5 Auto switch set value and its height 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 Auto switch Symbol 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 A B Hs A B Hs A B Hs D-B54 D-A93 Hs B A 33 D-M9B D-M9BW D-B54 12 Note 1) The
(V), D-A93(V), D-A96(V) Auto Switch Specifications D-A96 D-A90 D-A90V D-A93 D-A93V In-line D-A96V Auto switch part no.