SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-40-05-01T"

1 Auto Switch Guide Reed Switches/Solid State Switches For Rotary Actuators (Air Grippers) Applicable Auto Switch Auto switch mounting Applicable air grippers Applicable rotary actuators Auto switch model Electrical entry Page Type CRB2 Size Size CRBU2 30 50-100 10/15 20-40 10-40 32/40 1/3 7/20 10-200 05/1 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB2 CDRBU2 CDRQ2MRQ

40 40 40 80 80 Suction flow rate ZB Suction flow rate 20 20 20 20 40 40 ZA 0 0 0 0 0 0 10 20 30 40 50 60 Supply pressure [MPa] 0 0 20 40 60 80 Supply pressure [MPa] 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 ZX Suction flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] ZH18SA ZH18LA ZM Exhaust Characteristics Flow Rate Characteristics Exhaust Characteristics Flow Rate

Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.

bore size (mm) Part no. d H B C D Applicable bore size (mm) SO-02 SO-03 SO-04 SO-05 NT-02 NT-03 NT-04 AC-NI-50 8 8 9 11 20 25 32 40 M22 x 1.5 M24 x 1.5 M30 x 1.5 M33 x 2.0 30 36.9 43.9 47.3 26 32 38 41 5 6 8 10 12.5 16.5 21.0 23 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 15.0 19.6 25.4 27.7 26 32 38 41 13 17 22 24 Accessory Brackets (Optional) I-type single knuckle joint Bracket

/ Complex exhaust) 40 40 100 Vacuum pressure [kPa] 30 30 80 Air consumption 60 20 20 40 High-noise reduction silencer exhaust 10 10 20 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0 0 10 20 30 40 50 60 Supply pressure [MPa] Suction flow [L/min (ANR)] 19 Vacuum Unit ZK2mA Series The flow rate characteristics correspond to the standard supply pressure.

32 mm 40 40 mm 45 45 mm 50 50 mm 56 56 mm 63 63 mm 67 67 mm 80 80 mm 85 85 mm 100 100 mm For applicable auto switches, refer to the table below.

Model Tube material Bore sizes (mm) CHAW CHAFW 40, 50, 63, 80, 100 Aluminum alloy 40, 50, 63, 80, 100, 125, 160 Steel Easy position detection with auto switches Aluminum cylinder sizes 40 to 100 are auto switch capable for easy stroke position detection.

209 Speed Controller Needle Revolutions And Corresponding Cylinder Speed Special bracket For 100 stroke CKA40-40-21O For 150 stroke CKA40-40-2I I I , 600 :1 II 700 0 V I I ~ 500 .

The cost of producing a volume flow of .| r3"hin is then ffififW = 40 cents / hr. In our example: 0.336 m3ry'min 1mg/min . 40 cents / hr = 13.4 cents per hour.

The cost of producing a volume flow of .| r3"hin is then ffififW = 40 cents / hr. In our example: 0.336 m3ry'min 1mg/min . 40 cents / hr = 13.4 cents per hour.

Bore size (mm) 32, 40 50, 63 80, 100 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 BT-06 (1) MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 Foot A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)

Facility water system Electrical system Facility water temperature +27F (15C) Circulating fluid temperature Conditions 50 to 95F (10 to 35C) Facility water temperature 7.9 gpm (30 L/min) 1.1 gpm (4 L/min) 10.6 gpm (40 L/min) 10.6 gpm (40 L/min) Circulating fluid rated flow 5.3 gpm (20 L/min) 2.6 gpm (10 L/min) 6.6 gpm (25 L/min) 10.6 gpm (40 L/min) Facility water required flow rate Temperature

10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.

) BT-20 (200 Bore) our new part # C95D Tie Rod Mounting BT-03 (32/40 Bore) BT-05 (50/63 Bore) BT-06 (80/100 Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150 (1.5" Bore) NBT-200 (2" & 2.5" Bore) NBT-325 (3.25" & 4" Bore) "SC" auto switch CDQ2/NCDQ Direct Body Mount BQ-2 (32/40/50/63/80/100 Bore) Screw & Nut Kit included with cylinder "SC" auto switch CDRA1 Rail Mounting P294020-24 Screw & Nut

A to B C to D 3,000 L 30 to 3000 30 to 3150 40 to 4000 40 to 4200 L/min 6,000 L 60 to 6000 60 to 6300 40 to 4000 40 to 4200 12,000 L 120 to 12000 120 to 12600 40 to 4000 40 to 4200 PF3A7#H 3,000 L 1.1 to 105.9 1.1 to 111.2 40 to 4000 40 to 4200 cfm 6,000 L 2.2 to 211.9 2.2 to 222.4 40 to 4000 40 to 4200 12,000 L 4.0 to 424.0 4.0 to 445.0 40 to 4000 40 to 4200 : The flow ranges and relationship

16 64 24 3/8, 1/2 3(R) port 1/8 12(PA) port 18 67 2 x 6.2 (For mounting) NO 2A NC 53 66 12 12 3R NC 1P (1/8) 12(PA) port 11.5 16 115.1 107.1 24 96.5 95.5 32.5 M5 x 0.8 (Breathing hole) 16 X 40 3/8, 1/2 1(P) port 80 03 04 A B For vacuum/VPA744V-1l 3/8, 1/2 2(A) port 40 16 64 3/8, 1/2 3(R) port 24 18 67 2 x 6.2 (For mounting) NO 2A NC 53 66 12 3R NC 1P 1/8 12(PA) port 11.5 16 115.1 24 96.5

Bore size (mm) 32, 40 50, 63 80, 100 BT-06 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 (1) Foot MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)