Valve: None; Stop Valve: None, Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °C)
Valve; Stop Valve: None), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow:
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Stations: 6 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate
Stations: 6 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 1
Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out
Stations: 10 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 10 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 1 to 5
Stations: 4 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 0.5 to 4 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 1 to 5 V; Out 2