Refer to How to Increase Manifold Stations on page 23. (2) SI Unit Symbol Protocol FAN PROFINET KAN IO-Link EAN EtherNet/IP (3) End plate U supply (P) port Symbol Type Single Unit L8 8 One-touch fitting elbow LN9 5/16One-touch fitting elbow ZKJ 07 C8 H A 5 U T1 L (1) (2) (3) (4) (5) (6) (7) (8) (9) Remains blank when no option is selected. (1) Nominal Nozzle Size Symbol Nominal size 07 0.7
Byte63 L -71No.EX-OMN0027CN-D 1 7 6 5 4 3 2 1 0 Byte 0 0 Bit No. 0 1 1 1 2 1 3 1 4 1 5 (0) 6 1 7 1 2 7 6 5 4 3 2 1 0 Byte 1 0 1 Bit No. 0 1 1 1 2 (1) 3 1 4 1FREEZE 5 1SYNC 6 (0) 7 1 3 7 6 5 4 3 2 1 0 Byte 2 0 0 0 0 0 0 0 Bit No. 06 (0) 7 1 PROFIBUS DP Byte 3 PROFIBUS FFh ID Byte 45 IDEX600-SPRA ID 1411h -72No.EX-OMN0027CN-D Header 7 6 5 4 3 2 1 0 Byte 6 0 0 0 0 1 1 0 1 Bit No. 07
Applicable model P215420-07 For JT20 7 Dust cover P215432-07 For JT32 P215440-07 For JT40 Dimensions JT20 to 40 M, P D M E F C G A B H Standard Pneumatic: Up to 0.7 MPa [mm] Model Connection thread M A B C D E F G Width across flats H Maximum thread depth P Weight JT20 M8 x 1.25 19.2 8 11 (25.4) 23 10 13.6 22 9.5 22 g JT32 M10 x 1.25 23 10 13.4 (30.6) 28 12 16.3 27 11.5 38 g JT40 M14 x 1.5
The VM series is a mechanical, poppet valve. Their compact size requires little mounting space. The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Actuator replacements for VM100, VM200, VM400 and VM800, Roller levers, plungers, toggle levers, rod levers, push buttons and twist selectors, MECHANICAL VALVE, TWIST SELECTOR, MECHANICAL VALVE, 141 lb
.: 07 (ø1/4"), Actuator Type: 07 (Cross Roller Plunger)
.: 07 (ø1/4"), Actuator Type: 07 (Cross Roller Plunger), Suffix: S (Hard Steel Roller)
LED EX245-DY1 LED(8 )(07) 07 OFF OFF ON ON ON . 8-2 EX245-DY1 LED 54 No.EX-OMW0014CN-A 8.6. EX245-DY1 4M12(5 ,) (n+1) (n) FE/ 24 V(/) 0 V(/) 24 V(/) 0 V(/) FE . 8-3 EX245-DY1 55 No.EX-OMW0014CN-A 9.
LED EX245-DY1 LED8 07 07 OFF OFF ON ON ON . 8-2 LED 59 No.EX-OMU0020CN 8.6. EX245-DY1 4 x M12, 5-way sockets (0 to 3) N.C. DO (n+1) Output interface Short circuit protection 0 V DO (n) FE / Shield Output circuit / Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS . 8-3 EX245-DY1 60 No.EX-OMU0020CN 9.
IZN10 IZN10 IZN10 IZN10 01 01 01 01 P P P P 06 06 06 06 Z Z Z Z B1 B1 B1 B1 IZN10 AC 01 02 11 Rc1/8 NPN P PNP 06 6 07 6.351/4) 16 6 ( 17 6.351/4() (3m) Z (10m) N IZN10-NT L DIN IZN10A002 IZN10B1 L B2 B3 DIN 01 06 ES 2 01 ES 17mm 2 2 02 3 3 11 Rc1/8 4 4 /IZS30 /IZS30 /IZS30 /IZS30-M2 M2 M2 M2 06 6: 07 6.351/4: 16 6 :( 17 6.35(1/4):() IZN10-CP(3m) IZN10-CPZ(10m) IZN10A003 NPN
Alarm1 Water Leak Detect FLT 01 Alarm2 Incorrect Phase Error FLT 02 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10 Return High Temp WRN 10 Alarm11 Reservoir High Temp.
Nominal filtration rating: 30 m 0 to 101 kPa 100 to 100 kPa 849 Compact Vacuum Ejector Series ZA How to Order Ejector Unit ZA1 1 07 K1 P1 5 L 0 1 Nozzle nominal size Vacuum (V) port 05 07 0.5 0.7 Symbol 1 2 4 5 Applicable tubing O.D. Part no. KJS23-M5 KJS04-M5 KJL23-M5 KJL04-M5 3.2 (Straight) 4 (Straight) 3.2 (Elbow) 4 (Elbow) Solenoid valve combination (Refer to Table (1).)
], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]
This is a legacy product, and replaced byZH07DSA-07-N01-07, VACUUM EJECTOR, 1/4 SUP, VACUUM SERIES, ZH VACUUM EJECTOR, BF, ZH NOZZLE SIZE 0.7, .04620 lb
Blanking plate Common port Plug Individual port (Base) VVXA211-07 (Valve) VXA2121-00 (Blanking plate) VX011-001 1 pc. 6 pcs. 1 pc. The standard arrangement of manifolds should be placed on an individual port on this side, each solenoid valve from the left side and a blank plate in the right side.
Series ZMA How to Order ZMA 07 1 H K 5 T14 C Nozzle diameter Switch lead wires (connector type) 0.5mm 0.7mm 1.0mm 1.3mm 1.5mm 05 07 10 13 15 Lead wire length 0.6m Lead wire length 3m Without lead wires C CL CN Switch type Body type Without 1 point setting/analog output 3 rotations, NPN output T14 For single type Common SUP for manifold Individual SUP for manifold 1 3 5 Without 1 point setting
diameter C C CN Lead wire length 0.6 m Lead wire length 3 m No lead wire 05 0.5 mm 07 0.7 mm 10 1.0 mm 13 1.3 mm 15 1.5 mm ZL Refer to Table (2) for lead wire with 4-wire connecor.
Filtration 30 m ZQ107 0.7 ZQ110 1.0 13-9-1 2 Compact Vacuum Ejector Series ZQ How to Order ZQ1 07 5 D31 1U K1 L C Ejector unit Nozzle nominal size Check valve 05 07 10 Nil K None With check valve 0.5 0.7 1.0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Note) The
Note 1) Note 2) Nil 1 None With silencer Max. vacuum pressure Manual override S L 84 kPa 53 kPa Nil D E Non-locking push type Push-turn locking slotted type Push-turn locking lever type Nozzle diameter 0.7 mm 1.0 mm 07 10 13-8-4 5 Ejector Valve Unit Series ZYY/ZYX How to Order Ejector Valves for ZYX3000 Lead wire/ Voltage suppressor specifications Plug-in type Serial transmission type LOZ
Operating Valve (Air Supply & Release Valve) Pilot: VJ114 Vacuum Solid State Type ZSE1-0 Switch Diaphragm State Type ZSM1-0 Suction Filter 30m PE (Polyethylene) Lubrication Forbidden Solenoid Supply 24V DC H O W T O O R D E R (N)ZM V A C U U M E J E C T O R (N)ZM D I M E N S I O N S W I T H VA C U U M S W I T C H D I M E N S I O N S B A S I C T Y P E N O Z Z L E D I A M E T E R 05 0.5mm 07
How to Order ARM11A 3 1 A M Z 07 q w e r t y u i N 1. Knob Position 2. IN/OUT Piping Position OUT side fitting Elbow IN side OUT side Symbol Position Front Top Bottom IN side fitting Elbow Position Symbol Bottom Top Bottom Top Top A B C Top Front Bottom 1 2 3 4 Top OUT side fitting Straight IN side fitting Straight Bottom Bottom 3. Regulator Block Stations 4.