Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: C (Locking, Manual), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 2 (200VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 6 (12VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 3 (110VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: C (Locking, Manual), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: B (Locking, Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)]
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 1 (100VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: E (None), Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 4 (220VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv
Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Stations: 2 Stations, Port Size: 1/4, Thread: -
Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Stations: 5 Stations, Port Size: 1/4, Thread: -
Actuation: 3 (3 Position Closed Center), Mounting/Porting: 0 (Base Mounted), Seal: 0 (Rubber), Pilot Specification: Internal Pilot, Back Pressure Check Valve: None, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: Without light/surge voltage suppressor, Non-polar, Manual Override: Non-locking Push Type, A,B Port