Search Results "VSR8-6-FG-D-3EZ-V1-X1"

Body Size: 30, Thread: Rc, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard

Description Material KE Reference dimensions AS-FG 1 2 3 4 Body Valve Cap Needle Aluminum alloy NBR Rolled steel Brass POM Zinc alloy AS-FP AS-FM 5 Handle Replacement Parts AS-D No. Part no. Material 14284 NBR Description O-ring 6 AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 657

If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.

If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.

If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.

Be sure to ground terminal FG when using a commercially available switchmode power supply. When the switch-mode power supply is connected to the Pressure switch, switching noise will be superimposed and product specification can no longer be met.

If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected, switching noise will be superimposed and it will not be able to meet the product specifications.

Passage: FG (2-Position), Solenoid: D (Double), Voltage: 6 (220 VAC, 50/60Hz), Option: N (Indicator Light), Seal: R (Rubber Seal)

Passage: FG (2-Position), Solenoid: D (Double), Voltage: 6 (220 VAC, 50/60Hz), Option: Z (Indicator Light w/Surge Voltage Suppressor), Seal: R (Rubber Seal), Subplate: A03 (Side Ported 3/8)

AS-FE KE Elbow Universal 2 3 AS-FG Control type Applicable tubing O.D. Note) AS-FP Metric size Inch size Meter-out Meter-in 0 1 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 AS-FM 04 06 08 10 12 AS-D AS-T With One-touch fitting ASP Thread type M3 Port size Note) For applicable tubing O.D. selection, refer to the Model on page 484. Use 1/8" tube.

Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 5 32" Control type 04 06 08 10 12 03 05 07 09 11 13 3 16" Meter-out Meter-in 0 1 AS-FG 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.

This is a legacy product, and replaced byVS7-6-FG-D-CN

Seal Type: Metal, Configuration: 3-Posiiton, Closed Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: w/o Subplate, Option: External Pilot Supply

Seal Type: Metal, Configuration: 3-Position, Exhaust Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: w/o Subplate, Option: External Pilot Supply

Seal Type: Metal, Configuration: 3-Position, Pressure Center, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: w/o Subplate, Option: External Pilot Supply

Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Single, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/4, Option: External Pilot Supply

Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Single, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/8, Option: External Pilot Supply

Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions. Design Warning 1. When connecting the exhaust piping onto 3(R) port, confirm that the effective area is larger than the figure shown below. If the effective area is smaller than the figure listed below, back pressure will induce air leakage.

Tightening Torque for Operating Port Operating port Torque (Nm) After tightening by hand, tighten additional 1/6 rotation with a tightening tool. M5 Rc, NPT 1/8 0.8 to 1.0 2. Use the pilot ports and sensor (respiration) port as follows.