Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.

Also, do not drop or apply a strong shock. Otherwise, damage or an accident can occur. Also, do not drop or apply a strong shock. Otherwise, damage or an accident may occur. 7. Do not affix any tape or seals to the body.

Do not use a lead wire longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply. Operating environment Do not use the product in an environment where the product is constantly exposed to water or oil splashes. Otherwise it can cause failure or malfunction. Take measures such as using a cover.

Refer to each construction drawing on the fittings and tubing material. (2) Do not expose the product to direct sunlight for an extended period of time. (3) Do not use in a place subject to heavy vibration and/or shock. (4) Do not mount the product in locations where it is exposed to radiant heat. (5) Do not use the ordinary fittings and tubing in locations where static electricity would

Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. 2. Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5.

Note 12) Sensor magnet position is located in the table center. For detailed dimensions, refer to Auto Switch Mounting Position on page 142. Note 13) Do not allow collisions at either end of the table traveling distance. Additionally, when running the positioning operation, do not set within 2 mm of both ends. Note 14) For the manufacture of intermediate strokes, please contact SMC.

N-04 N-06 L-04 L-06 S-04 S-06 LL-04 LL-06 4 6 N-08 8 N-10 10 N-12 12 4 6 L-08 8 L-10 10 L-12 12 4 6 S-08 8 S-10 10 S-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 Precautions Be sure to read before handling.

(mm) B1 H LH LX 22 22 GA GB GC KA LD 138 109 107 103 1/8 AL MM X Y B 52.3 42.3 36.3 30.3 ND 20-0.033 0 7 5.5 5.5 5 K Bore size ZZ S P N L D A H1 I 17 17 13 34 31 31 27 6 6 5 18 15 25 21 8 8 6 6 8 6 5.5, 9.5 counterbore depth 6.5 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 49 43 43 39 15 12 12 12 104 78 76 76 42.5 34.5 30 24 14 12 10 8 58.5 47 39 33.5 21 19.5 19.5 15.5 40 32 25 20 24 22 22 18

Dimensions 43 25 10 Model (Standard) Pressure range (1) Indication unit Connection thread Note Model MPa G49-2-02 G49-7-02 G49-10-02 0 to 0.2 0 to 0.7 0 to 1.0 44 1 4 R MPa R 1/4 Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. 12 Other versions of this unit can be made on a made-to-order basis.

Note 5) For step data input, up to 12 controllers connectable.

Do not drop these products or submit them to strong impacts. This can cause damage, failure or malfunction. 12. Since these products are components whose end usage is obtained after installation in other equipment, the customer should confirm conformity to EMC directives for the finished product. 3.

Do not use a cable longer than 10 m. Wire the DC (-) line (solenoid valve: black, pressure switch: blue) as close as possible to the power supply. 12. Do not use the product in an area where surge is generated.

Extension locking (F) M3 x 6 11 2 x Rc1/8 Extension port 39 3 x Rc1/8 Retraction port Dust cover 20 60 25 34 + Stroke 5 6 12 53 4 12 Head end cushion valve 9.5 19 47 45 M10 x 1.25 40 12 47 10 26 Width across flats 10 26 Width across flats 36 R12 12 +0.5 +0.2 0.040 0.076 Shaft: 10d9 Hole: 10H8 26 12 6 +0.022 0 102 + Stroke 55 41.2 169 + Stroke 49 Note) Refer to page 14 and 15 for Accessories

Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5. Employ suitable protective measures in locations where there is contact with water droplets, oil, welding spatter, etc.

Do not use valves in atmospheres of corrosive gases, chemicals, salt water, water or steam, or where there is direct contact with same. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications for each series. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5.

Because standard types with voltage specifications other than 24 and 12 VDC do not have polarity protection diodes, be careful not to mistake the polarity when connecting lead wires. If the lead wires are connected beforehand, the red wire is +, and the black wire is .

Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 12. Do not use body A and/or elbow body for applications involving continuous rotation. Mounting Body A and the fitting section may be damaged. Warning 1.