Number of stations: 2 stations, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Right-angle cable
Number of stations: Triple, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 4 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: No bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: None
Number of stations: 2 stations, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Cable: Centralized lead wire (with bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Straight, Bracket Option: B (Bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: B (PNP, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: N (None), Bracket Option: B (Bracket)
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 6, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: N (None)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: N (None), Bracket Option: B (Bracket)
Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE79S (0 to 50 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE79S (0 to 50 MPa), Piping: F02 (G 1/4, ISO 1179-1 Compliant), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])