Double acting, guided actuator ; High temperature(XB6)Bore sizes(mm): 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 ; Slide bearing type ; Standard stroke range (mm): 10 to 400 ; Port threads: M (12 to 25 bore), Rc, NPT or G (32 to 100 bore) ; High temperature option (XB6) ambient range -10 to 150°
Manufacturers include Mitsubishi, Yaskawa, Sanyo Denki, Omron and Panasonic Body sizes: 40 (100W), 63 (200W), 100 (750W); Maximum workload: 55 kg (size 40), 85 kg (size 63), or 400 kg (size 100); Maximum speed: 2300 mm/s (size, lead, and stroke dependent); Maximum acceleration:: 20,000 mm/s² (40, 63) 9,800 mm/s² (100); Positioning repeatability: ±0.01mm (size and lead dependent); Stroke range
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz); 200~230; STO (Safe Torque Off) safety function available; Display and settings buttons for direct input and status monitoring; Compliant with SEMI F47 Standard; SigmaWin+ Configuration software required (download available separately)
Two models available: ZVB40 (single ionizer) = 210 W x 297 D x 351 H (mm), ZVB40 (double ionizer) = 400 W x 384 D x 390 H (mm); Static electricity removal performed by an IZN10 nozzle iionizer; Static neutralization in 1 second or less; Ion balance is ±10V; Accessories include exhaust hose, dust bag, and AC adapter
Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications
Power supplies are available in 200 and 400 VAC 3-phase, and function in both 50 and 60 Hz environments for global compatibility. Alarms report on a variety of circuit and equipment conditions to preserve optimal operation.
Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 100~120V no longer available; 200~230 (LECSS-S); 200~240 (LECSS-T); Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSS2-T only)
Positioning table points: 255; Compatible motors (W): 100/200/400; Power supply voltage (VAC, 50/60Hz): 200~230; Display and setting buttons for direct input and status monitoring; LEC-MRC2 Configuration software required (sold separately); C-UL-US listed (LECSC2-T only)
Body size: 25; Maximum work load: 9 kg (horizontal), 4 kg (vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 50, 100, 150; Positioning repeatability: ±0.05mm
Body size: 25; Maximum work load: 5 kg (horizontal or vertical); Maximum pushing force: 180 N; Maximum speed: 400 mm/s; Strokes: 30, 50, 75, 100, 125, 150mm; Positioning repeatability: ±0.05mm
Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications
EtherNet/IP™: AOI available for Studio 5000 Logix Designer; EtherCAT®: IEC61158 Type 12 CAN application protocol over EtherCAT® (CoE) and IEC61800-7CiA402 drive profile; PROFINET: includes PROFINET IO Real Time (RT); Compatible motors (W): 100/200/400/750; Power supply voltage (VAC, 50/60Hz): 200~240; Display and settings buttons for direct input and status monitoring; LEC-MRC2 Configuration
Body size: 8, 16, 25; Strokes: 50, 75, 100 or 150mm; Maximum work load: 12 kg (horizontal, 20 kg (vertical)); Maximum pushing force: 420 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm
Bore sizes: 16, 25, 40, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15 ~ 0.20 MPa (22 ~ 29 psi); Speed: 80~1000 mm/sec (w/o stroke adjustment bolt), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3M is compatible with secondary battery applications
Body size: 16, 25; Strokes: 50, 100, 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 385 N; Maximum speed: 400 mm/s; Positioning repeatability: ±0.01mm; Encoder resolution: 17-bit (S motors), 22-bit (T motors), 20-bit (V motors)
Body size: 16, 25; Strokes: 50, 100, 150mm; Maximum work load: 12 kg (horizontal), 20 kg (vertical); Maximum pushing force: 385 N; Maximum speed: 400 mm/s
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, up to 5000mm manufacturable stroke; Minimum operating pressure: 0.12~0.16 MPa (17~23psi); Speed: 50~500 mm/sec
Offered in an integrated or remote control type, the E-MY2 is available with 3 or 5-point accurate stop options (2-points for both ends, with the remaining points for any preferred intermediate stops), and a wide selection of standard strokes, speed rates, and applicable loads.Linear guide, single and double axis types ; Standard strokes (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the "easy mode".Body size: 25, 32, 40 ; Ball screw drive ; Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 ; High output motor (100/200/400W); Pulse input type
Double acting, single rod; Bore size (mm): 40, 50, 63; Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500; Rc, NPT or G port threads; Clean series