NPT 23 (R,NPT) Nm 1/8 35 1/4 812 3/8 1520 1/2 2025 3/4 2830 1 3638 11/4 4042 11/2 4850 2 4850 () 1 5 VEX-OMV0001 VEX1 Series / () 5 () 30 ( ) 6 VEX-OMV0001 VEX1 Series (904 ) 3.57 () (AF )(AMAFM ) ( ) 22 3 JIS C 3306 0.5mm () () IR2000 A VEX1 B33 VK300-82-1 ITV VY AC100V 100V VK300-82-2-01 AC110V 110V VK300-82-2-03 AC200V 200V VK300-82-2-02 AC220V 220V VK300-82-2-04 ) AC240V 240V
12 4 1) (BMA2-A)(BJ5-1/) () 2) (BMA2-AS/)(BJ4-1/) D-M9A(V) () BBA3:D-B5,B6,G5,K5 BBA4:D-C7,C80,H7 3)BBA3 Best Pneumatics No.
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
Auto Drain Valve AD402-A Series Specifications Standard Specifications Model AD402-A Auto drain type Float type Auto drain valve type N.C. (Normally closed: Drain port is closed when pressure is not applied) N.O.
The element can be replaced with a single touch. AMJ 30 0003 2R ZR ZM Body size Pressure gauge position 30 3/8 None Bracket Nil ZH 40 1/2 B Option 50 3/4 ZU Drain cock Nil Metal bowl 2 ZL Thread type Port size Nylon bowl 6 Drain guide (Rc 1/4) 02 1/4 Nil Rc J ZY 03 3/8 Flow: Right Left F G R 04 1/2 N If ordering two options or more, indicate symbols numerically and alphabetically.
For details, refer to the back of page 6, Procedure for replacing or changing the mounting angle of a pressure gauge. Mounting angle view (-R specification) MPa OUT IN K P C U O S L H to 2
Clearance of the nozzle y is reduced causing higher back pressure at diaphragm A u. This diaphragm A u has larger area than diaphragm B i resulting in movement of the spool to the left. Supply pressure then ows to OUT1 q and partial exhaust from OUT2 takes place resulting in cylinder rod t movement to the right.
override Nil Non-locking push type (Flush) A Non-locking push type (Extended) B Locking type (Tool required) DO DIN terminal (Without connector) For other rated voltages, please contact SMC.
Nil V Standard For vacuum X505 VPA500 series Port size Symbol Port size VPA300 1/8 1/4 3/8 1/2 VPA500 VPA700 01 02 03 04 Bracket Nil F Without bracket With bracket Thread type Type of actuation A B N.C. (Normally closed) N.O. (Normally open) Nil F N T Rc G NPT NPTF VPA700 series Specifications Air Fluid N.C. or N.O.
This is a legacy product, and replaced byAV2000-02-5DB-A, VALVE, SOFT START 1/4, VALVE, AV SOFT START UP BODY PORT, FA, AV BODY PORT 1/4 PT, .88184 lb, ModelPort sizeProof pressureOperating pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .00000 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating pressure
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SILENCER, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .02052 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating pressure
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 1/8 PT, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .04188 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER, M3, AIRLINE EQUIPMENT, AN SILENCER, 1B, AN OTHER SIZE STANDARD (PT), .00352 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER, M5 (NOM 10/32), AIRLINE EQUIPMENT, AN SILENCER, AB, AN M5, .01000 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER, AIRLINE EQUIPMENT, AN SILENCER, AB, AN M5, .00963 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating pressure
Series AN silencers offer various styles and low backpressure in a compact, easy mounting design. The noise reduction has been improved to 30 dB(A) and the case is UL94-V0 grade, flame resistant material. Series AN is available with M, R or NPT threads.
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 02, Port Size: 01 (Rc 1/8), Thread: T (NPTF)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 02, Port Size: 01 (Rc 1/8), Thread: N (NPT)
Solenoid Direction: Opposite side of A port (A port bottom ported for Type 40), Type: 42 (A Port Side Ported; 42S: Solenoids on the Same Side of A Port), Stations: 02, Port Size: C6 (ΓΈ6 Cassette)