SMC Corporation of America
Elite Part Number Search
Search Results "AC40C-N04G-V-RZ-A"

[How to JOG] a) Change the mode to Remote mode in the main window. b) From the main window select View (V), select the Teaching window and select the JOG tab. Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window.

-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 -69No.PF-OMN0011CN-C / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -70No.PF-OMN0011CN-C

A73C A72H A73H E76A E73A F79 F7P J79 F79W 200 V Relay, PLC 2-wire 100 V 12 V Yes 24 V Connector 3-wire (NPN equivalent) IC circuit 10 5 V Grommet 2-wire 24 V Relay, PLC 100 V 12 V F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 10 16 20 25 32 3-wire (NPN) 3-wire (PNP) 24 V IC circuit 16 20 25 32 5 V, 12 V Diagnostic

There is a danger of malfunction or damage to the reduced wiring system or input/output equipment. +24 V +24 V Power supply for output Power supply for output 0 V 0 V Power supply for control/input +24 V Power supply for control/input 24 V 4. Do not install a unit in a place where it can be used as a foothold.

-"()7 digit() 1 digit=1 kPa 1,2,3,,99,100 1 kPa 15[V] F.S.=514[V] (1F.S.=40.01=0.04[V]) F.S. () NPN()() NPN PNP()() PNP R.D. 1.000 5R.D.1.000 50.05 0.800 5R.D.0.800 50.04 ON OFF () (30 ) ON OFF Hysteresis ON-OFF /, () () 25[]ON-OFF (copy function) () -13No.PS-OMM0006CN-E NPN () () ()()( ) () ON ON 0 (1 k 1 M A/D 5 V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005 V ) 30 ON-OFF ON

If operating with a small induction load such as a relay, wire as shown in the figure below. (In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1.

AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.005 to 0.2 MPa V V 0.01 to 0.2 MPa V 1 0.01 to 0.4 MPa V V V 2 0.01 to 0.8 MPa V V V + ARM ARP IR-A IR-A e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR IRV r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH

AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.02 to 0.2 MPa V V V 1 0.02 to 0.4 MPa V V V 2 0.02 to 0.8 MPa V V V + ARM ARP e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR-A IR-A IR r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + IRV VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH t Port size SRP a

If operating with a small induction load such as a relay, wire as shown in the figure below. (In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1.

110 V [115 V] 200 V 220 V [230 V] 4(A) (B)2 2(B) (A)4 Apparent power (VA) AC 5(R1) (R2)3 1 (P) (R1)5 1 (P) 3(R2) Diode (DIN terminal, Varistor when non-polar types) LED (Neon light when AC with DIN terminal) 3 position exhaust center 3 position exhaust center Surge voltage suppressor Indicator light 4(A) (B)2 2(B) (A)4 Common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

G T L S M kit (Flat ribbon cable with terminal block) kit (Terminal box) kit (Lead wire) kit (Serial transmission unit) kit (Multi-connector kit) Number of pins: 20 (VQ2000 only) 2-4-113 Valve Specifications Sonic conductance Type of actuation Voltage Electrical entry Manual override C [dm3/(sbar)] 4/2 5/3 (A/B R1/R2) 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz Push type

Install a micro mist separator or super mist separator on the outlet side (end terminal) of the membrane air dryer (unit). Grease is applied inside a regulator used in the unit (V type).

Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.

If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

, D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Switch operating range A B A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main

500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.

12 V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)