(Example) NVV3J1-S41-03-M5 NVJ114-5M2.. . 2 VJ100-19-1A .. . 1 a lt is impossibie to mount NVJ | 14O and NVJ124O together on the same manitold base. . In cas of NVJ124O manifold type, supply air to "R" port of manifold base, "P" port of maniiold base will be lhe exhaust Dort.
Body Size: 40, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: J (Right Angle Square Type Pressure Gauge w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Body Size: 40, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: BJ (w/Bracket, Right Angle Square Type Pressure Gauge w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-89 kPa), SUP: 03 (Screw-in Rc 3/8), VAC: 03 (Screw-in Rc 3/8)
Body Size/Type: 32 (Elbow Size 03 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: G (G), Port Size: 03 (3/8), Applicable Tubing O.D: 10 (ø10)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: Rc, Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Body Size: 40, Backflow: without Backflow Function, Thread: N (NPT), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: E1 (Output: NPN output / Electrical entry: Wiring bottom entry), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Y (Upward), Pressure Unit: ZA (Digital Pressure Switch: w/Unit Selection Function)
Body Size: 40, Backflow: without Backflow Function, Thread: N (NPT), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: BE1 (w/Bracket + Output: NPN output / Electrical entry: Wiring bottom entry), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Y (Upward), Pressure Unit: ZA (Digital Pressure Switch: w/Unit Selection Function)
Body Size: 40, Backflow: without Backflow Function, Thread: N (NPT), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: w/o Mounting Option, Set Pressure: 1 (0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 03 (3 Stations), Supply/Return Unit Layout: U (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Body Size: 40, Backflow: without Backflow Function, Thread: F (G), IN Port Size: 03 (3/8), OUT Port Size: 03 (3/8), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Stations: 03 (3 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
Piping: 1 (Bottom Direction), Body Color: W (Urban White), Piping Type: Rc, Connection Size: 03 [Screw-in (Port Size 3/8)], Nozzle: 03 (Male Thread, KN-R02-200)
Suitable for applications where copper free specifications are required, the in.ûFGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric
Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines