Nozzle Diameter: 05 (ΓΈ0.5mm), Vacuum Pressure: S (-90 kPa), SUP: 01 (Screw-in Rc 1/8), VAC: 01 (Screw-in Rc 1/8), EXH: 01 (Screw-in Rc 1/8), Accessories: N (w/o Bracket, w/o Silencer)
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 Flow
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.12125 lb
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
(RES) A.10 Undervoltage A.12 Memory error 1 (RAM) A.13 Clock error A.15 Memory error 2 (EEP-ROM) A.16 Encoder initial communication error1 A.17 Board error A.19 Memory error 3 (Flash-ROM) A.1A Motor combination error A.1C Software combination error A.1E Encoder initial communication error 2 A.1F Encoder initial communication error 3 A.20 Encoder normal communication error 1 A.21 Encoder normal
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.
1 2 Holding block (A) 1 2 1 Switch block (A) 1 1 Switch block (B) 1 1 Holding block (A) 1 No.
When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. The switch does not have explosion proof structure, so do not use flammable gas. Otherwise, fire may occur. 5. Monitor the internal voltage drop of the switch.
Remote modeOpen A The time of FLT alarmClose FLT Operation stop FLT alarm status signal B The time of FLT alarmOpen A The time of WRN alarmClose WRN Continuing operation WRN alarm status signal B The time of WRN alarmOpen ALM Alarm status signal A The time of alarmClose B The time of alarmOpen RDY TEMP READY signal A TEMP READY statusClose B TEMP READY statusOpen A EnabledClose FREZ Anti-freezing
Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.
Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. longer simultaneously, the main display shows [-], and the reset to zero.