Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT, DIN (AC
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa), Effective area mm 2 (Cv): metal seal 2.2 (0.12) - 16.2 (0.9); rubber seal 3.6 (0.2) - 21.6 (1.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
However, a constant pressure of 200 kPa (0.2 MPa) or more should be avoided. Operating Environment Warning 1. Do not use in an area, where surges are generated.
Specifications Air Fluid Max. 50C Ambient and fluid temperature (C) Response time (ms) (1) 10ms or less Base mounted 20 Max. operating frequency (Hz) Manual override Non-locking push, Locking slotted, Push-locking slotted, Push-locking lever Not requited Lubrication JIS Symbol Free Mounting position Impact/Vibration resistance (m/s2) (2) 150/30 SY11 (A) 3 4 SY12 (A) 3 4 Dust-proof Enclosure
Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style
A Right Model Arm opening angl CKZT25-105-DCL781EL 105 B CKZT25-90-DCN7018N CKZT25-45-DCN7017N 90 45 30 CKZT25-30-DCN577NN Left C Relation between Shim Thickness and Clamping Force Arm length L (Note) The self lock does not function when a shim, which is beyond the peak clamp force position in the graph, is inserted.
7 Piston rod Miniature linear guide Table Bumper A Bumper B Bushing Steel ball A Steel ball B Type C snap ring for hole Round head Phillips screw Magnet holder Auto switch Piston gasket Rod seal Piston seal Gasket r t y u i o !0 !1 !2 !3 !8 !
TS0425TS0604TS0806TS1075TS1209TISA01TISA05TISA07TISA11TISA13 Color 100 m reel 150 m reel 200 m reel 500 m reel 20 m roll Black, White, X3 Red, Blue, Yellow, Green X4 Red, Blue, Yellow, Green 464
Positive pressure ISE2 ZSE2 Vacuum Piping specifications Wiring specifications Single mounting R 1/8 Note 2) Grommet type (Lead wire: 0.6 m) 01 Nil Single mounting NPTF 1/8 Note 2) Grommet type (Lead wire: 3 m) T1 L Connector type (Lead wire: 0.6 m) 0X C W/suction filter (Mounting on ZX unit) M5 x 0.8 Connector type (Lead wire: 3 m) W/suction filter (Mounting on ZX unit) M6 x 1 (Option) 0XY
VAC 3 110 VAC 4 220 VAC 5 24 VDC 6 12 VDC 7 240 VAC 8 48 VAC B 24 VAC J 230 VAC T Terminal (With surge voltage suppressor) TL Terminal with light (With surge voltage suppressor) C Conduit (With surge voltage suppressor) Table: Spacer Part No.
Piston Speed Standard Stroke Bore size (mm) 16 25 40 63 20 32 50 Bore size (mm) Max. manufacturable stroke (mm) Standard stroke (mm) 80 to 500 mm/s Without stroke adjustment unit (MY3A) 80 to 1000 mm/s Without stroke adjustment unit (MY3B) 16, 20, 25 32, 40, 50 63 100, 200, 300, 400, 500, 600 700, 800, 900, 1000, 1200 1400, 1600, 1800, 2000 3000 80 to 1000 mm/s (16, 20 L unit: 80 to 800 mm
[UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply. 50 50 to to 1000 1000 * Refer to the applicable stroke table. y Motor option Nil Without option B With lock Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950