Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~20, Compatible Fluid: Water / Air / Chemical, Outer Diameter D(Ø): 16, Inner Diameter Class: ~15, Inner Diameter d(Ø): 13, Number of Cables(per piece): 1, Material: Fluororesin: [Standard Fluororesin] PFA ( tetrafluoroethylene, perfluoroalkoxy
Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~20, Compatible Fluid: Water / Air / Chemical, Outer Diameter D(Ø): 19, Inner Diameter Class: ~20, Inner Diameter d(Ø): 16, Number of Cables(per piece): 1, Material: Fluororesin: [Standard Fluororesin] PFA ( tetrafluoroethylene, perfluoroalkoxy
Type: Straight, Material: Fluororesin, Cutting Service: Not Available, Color: [Transparent (Including Non-Whites)] Translucent, Outer Diameter Class: ~30, Compatible Fluid: Water / Air / Chemical, Outer Diameter D(Ø): 25, Inner Diameter Class: ~30, Inner Diameter d(Ø): 22, Number of Cables(per piece): 1, Material: Fluororesin: [Standard Fluororesin] PFA ( tetrafluoroethylene, perfluoroalkoxy
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
With the use of D-sub output blocks, a maximum of 9 remote D-sub manifolds can be attached to one EX600 communication module. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
With the use of D-sub output blocks, a maximum of 9 remote D-sub manifolds can be attached to one EX600 communication module. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
The SQ plug lead units are available with D-sub connector, flat ribbon cable connector or PC wiring system compatible flat ribbon cable kits.Fluid: Air/inert gas , Maximum operating pressure: 0.7MPa , Effective area mm² (Cv factor):0.40 to 0.71, Coil rated voltage: 12, 24VDC , Power consumption (current): 24VDC; 0.4W DC (17mA), 12VDC; 0.4W DC (34mA) , Ambient & fluid temperature: -10 to 50
(Or None in the Case of No Switch), Valve Voltage: 1 (100VAC 50/60HZ), Solenoid Style: W (2 Position Double), Valve Type: D (DIN Connector)
(Or None in the Case of No Switch), Valve Voltage: 2 (200VAC 50/60HZ), Solenoid Style: 2 Position Single, Valve Type: D (DIN Connector)
(Or None in the Case of No Switch), Valve Voltage: 1 (100VAC 50/60HZ), Solenoid Style: W (2 Position Double), Valve Type: D (DIN Connector)
Magnet: D (Built-in), Mounting: D (Double Clevis), Style: N (Non-lube), Bore Size: 50mm, Port Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Valve Voltage: 1 (100VAC 50/60HZ)
(Or None in the Case of No Switch), Valve Voltage: 1 (100VAC 50/60HZ), Solenoid Style: 2 Position Single, Valve Type: D (DIN Connector)
(Or None in the Case of No Switch), Valve Voltage: 2 (200VAC 50/60HZ), Solenoid Style: 2 Position Single, Valve Type: D (DIN Connector)
(Or None in the Case of No Switch), Valve Voltage: 1 (100VAC 50/60HZ), Solenoid Style: 2 Position Single, Valve Type: D (DIN Connector)