5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)100 mA or lessIP65Operating: 0 to 50C, Stored: ?
, 2" , NPN or PNP open collector, 1 output + analog , Flow rate (l/min): 150~3000, 300~6000, 600~12000, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, HB, IF/PFA 1 INCH NPT VERSION, 3.08647 lb, ModelMeasured fluidDetection typeRated flow range Note 1)Minimum set unit Note 1)Note 2)Display unitsOperating pressure rangeProof pressurePressure lossAccumulated flow
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE MECHL 1/4 PT, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .63800 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE, SOL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .71650 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE, SOL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .83775 lb
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?
1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?3C)Lights up when switch output is turned ON. OUT1: Green, OUT2: RedIP40Operating: 0 to 50C, Stored: ?