SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R4Y-6E2U-1-10"

Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type

ON OFF 2 3 4 6 1 2 4 8 5 10 0.5 ON:SEC OFF:MIN 0.5 IDFA100F150F 4 4 4.2 IDX-OM-U022 5. 5.1 3 ON OFF (R) OFFON 3 2 R T 5.2 60cm 1 5.2 5.2 10% 5.2 IDFA100F150F 5 1 5.1 IDX-OM-U022 5. ( ) ( ) 60cm 1 10% 3 ( ) 60cm 1 2 INOUT INOUT () IDFA100F150F 5 2 5.1 IDX-OM-U022 5. 5.2 1-3 5.1 3.7 OFF () ON OFF ON IDFA100F150F 5 3 5.2 IDX-OM-U022 5. 5.3 R () OFF OFF OFF ON

Model Cushion Bore size (mm) 6 10 16 Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Rubber Air 10-/21-CDU6 10-/21-CDU10 10-/21-CDU16 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 10-/21-CDU20 20 5, 10, 15, 20, 25, 30, 40, 50 10-/21-CDU25 25 Non-lube Double acting Single rod M5 x 0.8 11-/22-CDU6 11-/22-CDU10 11-/22-CDU16 6 10 16 5, 10, 15, 20, 25, 30

MB C95 CA1 CS1 Standard stroke (mm) Rod end thread With thread Without thread B 5, 10, 15, 20 5, 10, 15, 20, (25), 30 6 10, 15 CJP D 10 15 F CDJP D 10 15 F 90 S With Auto Switch Number of auto switches Action Air cylinder with auto switch S 2 1 Mounting Bore Size * 5 stroke: S type only With auto switch 6 10 15 6mm 10mm 15mm Symbol Mounting Standard B F L D T Basic Flange Foot Clevis Trunnion

8 1 8 ARM1000 57 1 8 1 8 IRV 1 4 1 8 ARM2000 136 1 8 1 8 VEX How to Order SRH ARM 1000 A1 5 01 G SRP Semi-standard Regulator for manifold Nil 1 0.7 MPa setting (Standard) 0.2 MPa setting SRF Number of stations Note 1) Pressure gauge for 1.0 MPa is used.

hole) 2 2.2 die-cast hole (For manifold gasket positioning) 1/8 (EA, EB port) SYA7120-02 1/4 (A, B port) 5-2-15 14 Series SYA3000/5000/7000 Series SYA7000: Body Ported 2 position double SYA7220C8, N9 C10, N11 1/8 (Pilot port) One-touch fitting (A, B port) 2 4.2 (For manifold mounting) Applicable tubing O.D.: 8, 5/16" 10, 3/8" Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San

AR425 to 935 ARX AMR Winding direction ARM Sealant tape Expose approx. 2 threads ARP Recommended Proper Torque [Nm] Connection thread 1/8 1/4 3/8 1/2 Note) IR-A IR-A Torque 7 to 9 12 to 14 22 to 24 28 to 30 Note) Tightening force for connecting to the EXH port of IR301 2 -A is 8 to 10 Nm. Operating Environment IR Warning IRV 1.

IBV1 Series SMC Corporation 1.Index 1Table of contents P1 2Specifications P2 3Features P2 4External dimensions drawing P3 5How to mount a nozzle P4 6Relationship between Upstream Piping and Peak Pressure P5 7Safety Instructions P6~10 1 2.

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series

Nq Body size 10 20 25 30 40 Symbol Description Nw Pipe thread type Nil Metric thread (M5) V Rc V V V V N NPT V V V V F G V V V V + M5 M5 V 01 1/8 V 02 1/4 V V V V 03 3/8 V V V 04 1/2 V 06 3/4 V + Ne Port size a Mounting Nil Without mounting option V V V V V B Note 2) With bracket V V V V V H With set nut (for panel mount) Note 3) V V V V V + Option Note 1) Nr Nil Without pressure gauge

Symbol 0 P Side 1 E Side Side Bottom (1) Side Other A, B Side 9 Note 1) Size of A, B port bottom ported: Rc 3/8, 1/2 Option Stations Base specifications 2 1 Individual exhaust Common exhaust 02 2 stations 10 10 stations How to Assemble Manifold To order valves and blanking plate assembly mounted onto the manifold, list valves and blanking plate assembly with manifold base part number.

Valve stations are numbered from station 1 on the D side. Indicate the valves to be mounted below the manifold part number, in order starting from station 1 as shown in the drawing.

(Default setting) Number of occupied valve 8 outputs Number of occupied valve 16 outputs Number of occupied valve 24 outputs Number of occupied valve 32 outputs Mode OFF OFF OFF ON ON ON 1 2 3 4 5 6 7 8 ON 2 1 0 1 ON/OFF : : Mark C on the unit Mark B at cable end Mark A at cable end OFF OFF ON (1) Input data + System diagnosis + Unit diagnosis (up to 10 units) Input data + System diagnosis

DESCRIPTION CODE PDE3-S PDE5-S PDE8-S PDE10-S PDE15-S PDE20-S Condensate Y type drain filter 64355FF011 1 1 1 1 1 1 Fan motor 5210135005 1 1 Fan motor 5210135010 1 1 1 1 Fan of the fan motor 521505 1 1 Fan of the fan motor 5215019 1 1 1 1 Fan grid 5225010 1 1 1 1 DMC11 Air Dryer Controller 5620130100 1t 1t 1t 1t 1t 1t Dmc11 probe 5625NNN020 1t 1t 1t 1t 1t 1t Condensate drain solenoid valve

No.PS-OMG0001CN-H // PSE300 2 8 9 10 10 12 14 16 19 21 23 24 31 31 33 -1No.PS-OMG0001CN-H *1) (ISO/IEC) (JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating

size Symbol Thread type 1 8 1 4 B ZFA200 ZFA100 Nil T Rc B NPTF F G ZFA200 How to Order Manifold (2 to 10 stations) Symbol Indicate both the symbols for air suction filter and bracket part no.

(Max. 700mm) Class M1.5 [Class 1] 10 10 0.01 0.1 1 10 Particle diameter (m) No impact shock Note 1) This figure indicates the level of cleanliness inside the measurement chamber. Note 2) The vertical axis shows the number of particles per unit volume (1m) of air which are no smaller than the particle size shown on the horizontal axis.