Control unit: With control unit (supply port: left side), Number of stations: 2 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Square embedded type pressure
Control unit: With control unit (supply port: left side), Number of stations: 4 stations, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Regulator: Square embedded type pressure
Control unit: With control unit (supply port: left side), Number of stations: Triple, Option: With Bracket, Voltage(V): 24 DC, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 1 output, Unit specification for pressure values: SI unit fixed, Regulator: Square embedded type pressure gauge with regulator
(at 24 VDC) Input OFF voltage/input OFF current 5 V or less/1.5 mA or less (at 24 VDC) Rated input current Approx. 7 mA Internal current consumption 200 mA or less (when the input signal is ON) Display Green LED (Lights when ON) Sensor connector EX500-DXPA: M8 connector (3 pin, socket) EX500-DXPB: M12 connector (5 pin, socket) Short circuit protection Available Enclosure rating IP67 Body
Specifications Table 12-1 EX245-DY1 specifications Item Description General Dimensions (W x L x H) in mm 54 x 120 x 61 Weight 280 g or less Housing material Nylon, PBT Electrical Rated supply voltage 24 V DC Voltage drop to load supply Max. 1.6 V Internal current consumption at 24 V DC 50 mA or less Load connection 4 x M12, 5-way sockets with double allocation Over Voltage protection Yes,
Table 11-1 EX245-DX1 (W x L x H) mm 54 x 120 x 61 280g , PBT 24 V DC 1.6 V 50 mA 8 x M125 A code 2 / US1 30V /1 0.5A /1 2 A 1 16 PNP ON 11 to 30 V OFF -3 to 5 V 1.5mA ON Typ. 4.5 mA 24VDC 71 No.EX##-OMY0006CN 11.3. /SI IP65M12 M12,5 , Table 11-2 EX245-DX1 (TOP View) 1 24 V 2 2 DI ( n+1) 3 5 1 3 0 V (US1) 4 DI (n) 4 5 FE/ 11.4.
Tighten the connector by hand. -23No.PF-OMV0006-B Examples of Internal Circuit and Wiring NPN output type Max.28 V, 80 mA Internal voltage drop 1 V or less PNP output type Max.80 mA Internal voltage drop 1.5 V or less Used as IO-Link device : Numbers in the figures show the connector pin layout.
The default setting is OFF. 12. 4-20 mA mode When the operation (Target position operation) where the cylinder is operation by input current (4-20mA) is performed, set the Operation mode (Menu Tree No.1-3-5-2) to 4-20mA. Refer to 7-3. Target Position Operation for the signal input method. 13.
Two wire sensor connection Possible Logic0allowable current IL Max. 2.5 mA Input delay time 3 msec.
(at 24 VDC) Input OFF voltage/input OFF current 5 V or less/1.5 mA or less (at 24 VDC) Rated input current Approx. 7 mA Internal current consumption 200 mA or less (when the input signal is ON) Display Green LED (Lights when ON) Sensor connector EX500-DXPA: M8 connector (3 pin, socket) EX500-DXPB: M12 connector (5 pin, socket) Short circuit protection Available Enclosure rating IP67 Body
current signal 1 Typ. 4.5 mA -40No.EX##-OMU0020-A 7.3.
voltage: 1 V or less Maximum load current: 150 mA Residual voltage: 1 V or less (Load current: 150 mA) Maximum applied voltage: 26.4 VDC Maintenance signal output Error signal output (Load current: 150 mA) Ambient temperature Operating: 0 to 50oC, Stored: -10 to 60oC Ambient humidity Operating, Stored: 35 to 80% RH (no condensation) Material Case: ABS/Stainless steel, Emitter: Tungsten Weight
. -13No.PS-OMO0002-A Internal circuit and wiring example -21 Switch output NPN open collector output 2 outputs Max. 30 V, 80 mA -22 Switch output NPN open collector output 2 outputs Max. 30 V, 80 mA Analog output: 1 to 5V (5%F.S.)
Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 kW = 6 V Example: Load impedance is 3 kW. Leakage current from auto switch is 1 mA.
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse
2.0% F.S. or less (0 to 50C, based on 25C)NPN open collector Max. load current: 80 mA; Max. applied voltage: 30 V; Internal voltage drop: 1 V or less (with load current of 80 mA)PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA)NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulseON time per pulse