Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Body Class: ø4 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/8" or ø3, Output Tube Size: None, Pilot Port Thread: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: None, Option 2: Buffer Material FFKM
Body Class: ø4 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/4", Output Tube Size: None, Pilot Port Thread: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: None, Option 2: Buffer Material FFKM
Body Class: ø8 Orifice, Valve Type: N.C., Fitting Type: LQ2, Body Class: 2, 3, 4, 5, Tube Size: 1/4", Output Tube Size: None, Pilot Port Thread: LQ1 Integral Fitting, 1/8" (3mm), Pilot Port Direction: Direction 1, Option 1: None, Option 2: Buffer Material FFKM
Body Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.2, Supply Valve/Release Valve: N.C. / N.C., Pressure Sensor/Digital Pressure Switch for Vacuum Spec: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C [Common Wiring (plug-in) - w/o Lead Wire with Connector
Body Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.2, Supply Valve/Release Valve: N.C. / N.C., Pressure Sensor/Digital Pressure Switch for Vacuum Spec: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C [Common Wiring (plug-in) - w/o Lead Wire with Connector
Body Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve/Release Valve: N.C. / N.C., Pressure Sensor/Digital Pressure Switch for Vacuum Spec: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only, Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector
Body, Exhaust Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø0.7, Air Operated: Air Operated, Supply Valve; N.C; Release Valve: N.C., Vacuum Sensor: Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs, Connector: For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire, Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body, Exhaust Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.5, Air Operated: Air Operated, Supply Valve; N.C; Release Valve: N.C., Vacuum Sensor: Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs, Connector: For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire, Vacuum, V Port: 07 [ø1/4 One-touch Fitting
Body, Exhaust Type: Single Unit - Silencer Exhaust, Nominal Nozzle Size: ø1.5, Air Operated: Air Operated, Supply Valve; N.C; Release Valve: N.C., Vacuum Sensor: Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs, Connector: For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire, Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Connector: L-type Plug Connector Lead Wire w/Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release Pressure Supply
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; Self-holding, Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Connector: L-type Plug Connector Lead Wire w/Connector, Vacuum, V Port: Metric Size, ø6 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release
System: Vacuum Pump System, Single Unit, Valves: Supply Valve; Self-holding, Release Valve; N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Connector: L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch, Vacuum, V Port: Metric Size, ø8 One-touch Fitting, Bracket: w/o Option, Pump System PE Port Female Thread