Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 150 (1 1/2"), Stroke: 125 (1 1/4"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 130, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type
Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type
Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Lock Position: With head-end lock, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Lock actuation system: Non-locking type
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: M9B, Lead Wire Length(m): 1, The number
Through-hole (standard), Port thread type: Rc, Body Options: With rubber bumper, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Custom-made Specifications: None, Type: Pneumatic type, With/without connector: -, Auto switch mounting slot: Yes
cushions on both sides, Operating Pressure(MPa): -, Specification: -, Support bracket: Basic type, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None, Locking Direction: Bidirectional
cushions on both sides, Operating Pressure(MPa): -, Specification: -, Support bracket: Foot type, Port thread type: G, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: APC, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None, Locking Direction: Bidirectional
Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Foot, Rod Tip Shape: Male thread, Custom-made Specifications: None, Type: Short type
: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional