SMC Corporation of America
Elite Part Number Search
Search Results "FH340-03-110-P005"

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (AC), VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50C, VALVE, BODY PORTED, IP65 (AC), VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE

Size B d d C l 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 8 10 10 14 M10 X 1.25 19.6 21.9 25.4 31.2 16.5 18 21 26 25 32 40 50, 63 6 7 8 11 23 27 31 38 25 32 40 50, 63 17 19 22 27 7.6 9.6 9.6 13.4 18.2 22.2 26.2 32.2 CD-MU02 CD-MU03 CD-MU04 CD-MU05 NT-03 NT-MU03 NT-04 NT-05 M12 X 1.25 M14 X 1.5 M18 X 1.5 A nut is attached with rod end male thread as standard.

None (with plug) G1 G2 K40A-MP1.0-N01M K40A-MP1.0-N01M Body size Port size (OUT side) 2500 3000 Symbol Port size 02 03 NPT 1/4 NPT 3/8 Applicable model NARM2500 NARM3000 Number of stations 02 2 stations Piping 10 10 stations Symbol A B Type Common IN IN From end plate Below: OUT port or G port Individual IN NARM3000 Standard Specifications Proof pressure psig (MPa) 220 (1.5) Max. operating

04 06 10 Type 1 8 ASS100/110 ASS300/310 ASS300/310 ASS500 ASS500/600 ASS600 ASR PAT.PEND 1 4 00 10 Meter-out control type Meter-in control type Meter-in type is available only for ASS110 and ASS310. 8 3 ASF 1 2 3 4 1 JIS Symbol Thread type Rc NPT G Nil N F Meter-in control Meter-out control Caution Be sure to read before handling.

Function: 3 (3 Position Closed Center), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 0 (Standard for Base Mounted Type), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3),

Function: 3 (3 Position Closed Center), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 0 (Standard for Base Mounted Type), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct

Function: 3 (3 Position Closed Center), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 0 (Standard for Base Mounted Type), Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3)

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3), Thread: T (

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: DO (DIN Connector w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3), Thread

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported

Function: 3 (3 Position Closed Center), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 03 (Sub-plate Plug-in 1/8, Non Plug-in 3/8, Direct Ported P,A,B Ports 3), Thread: