23.4 32.7 (32.8) AS221F-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 19 (20) AS221F-02-10(S)A 10 15.9 26.9 36.2 (36.3) 15.6 20 (21) AS321F-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS321F-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS321F-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS321F-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS321F-03-06(S)A 6 10.4 21.8 32.1 36.4 50 48.4 44.5 42.9 1/4 19 16.6 13.3
Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60C. IDU3D to 6D: 60C IDU8D to 37C1: 55C IDU55C, 75C: 50C Series IDF Can accommodate an inlet air temperature of 40C System efficiency is improved by using a high performance heat exchanger.
Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire. Do not modify the internal electrical wiring of the product. 10.2 Specifications An earth leakage breaker is installed in the product.
Weight reduction -30 to 40%(Company's ratio) Substantially shorter overall length 15 to 20mm reduc tion(Company's ratio) .Gaiters are unnecessary. Because a heavy duty cOil scraper is provided as a countermeasure against spatter, gaiters are unnecessary .
Do not use in the following environments, as it may lead to a breakdown. It may lead to damage or malfunction. An environment where corrosive gases, organic solvents, chemical agents or solutions are present, or a location where these substances may come into contact, and locations where sea water, water or moisture are present. An area exposed to direct sunlight.
Fine Lock Cylinder with Guide Series MLGC 20, 25, 32, 40 A linear transfer cylinder unit with a built-in locking mechanism and a guide rod integrated in a compact design.
VQ550 Indicator light Indicator light 214 121.8 195 (200.5) 91.5 59.5 105.8 (Port A) 17.5 13.5 (Port B ) 2 2 73 (78.5) 122 106 59.5 (Port A) 17.5 13.5 (Port B) 2 4 SMC SMC 2 4 A B 40 53 66 162 50 41 37 31.5 18 A B A B 53 66 40 B A 1 3 5 14 12 35 53 2-6.5 Mounting hole Manual override 5 1 3 12 14 Manual override 35 53 2-6.5 Mounting hole G1/2 Electrical entry 18 31.5 37 41 50 98 G1/2 Electrical
Auto switch type Clean room series Relief type A + Stroke B + Stroke Dimensions (mm) A B GB Bore size 40 63 100 58 48.5 36.5 GB 73 61.5 38 78 66.5 38 Dimensions not listed above are the same as the standard model.
Actuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Effect of back pressure when using a manifold Use caution when valves are used on a manifold, as actuator malfunction due to back-pressure may occur.
Reference page Item 3 Output type Example of internal circuit and wiring 4 Auto shift function, Chattering prevention function 5 Measures to be taken when error occurs 6 11 For General Fluids High Precision Digital Pressure Switch Series ZSE60F/ISE60 Dimensions Bracket A A 30 20 20 45 55 4.5 11.5 40 15 4.5 6.5 1.6 20 41.5 Bracket A ZS-24-A View A Bracket D A 30 20 20 45 55 4.5 4.2 11.5 40
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines. Thus, in the case of an error, each valve can be turned OFF to minimize the influences on other pads.
For a product without an external stopping mechanism, if a directional control valve is closed to keep the air pressure in the product, in an attempt to stop the product at midpoint, it might not be possible to maintain that stopped position due to an air leakage. As a result, it could pose a hazard to humans and cause damage to machinery and/or equipment.
Local Area: (800) 258-9200-www.stevenengineering.com 6H9 +0.030 7 (Hexagon socket head taper thread plug) 0 48 98 72 41 8 Operating port Rc 1/8 25 40 40 40 (Y) (Y) 10 Operating direction (B) 6H9 +0.030 depth 5.5 0 41 160 (Hexagon socket head taper thread plug) 10.5 Operating direction (B) (A) 9.5 11 24 24 16 12.5 A 30.5 60 50 32.5 A Cross section AA Z 5-M6 x 1 thread depth 12 4 x H G depth
exhaust center (B) 2 (A) 4 (B) 2 (A) 4 (Example) SS5YJA3-41-03-M5 1 pc.
OFF: Position data is handled as an absolute value. ON : Position data is handled as an incremental value. Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.)
B PF3W504 0 4 PF3W520 0 16 PF3W540 0 40 PF3W511 0 100 Display A Set A and B to the values shown in the table on the left.
Note) The -X126 model cannot be manufactured with an L plug connector for electrical entry. Therefore, use a grommet type or an M plug connector.
The first response time when the valve is not used for a long period of time 2. When using in an environment where the ambient and fluid temperature is low (10C or less) Note 4) The weight of a single unit of the valve includes a built-in EXH port silencer. Note 5) The flow rate of the body ported product with an external pilot decreases by 10%.
LEF How to Order LEJ LEL S2 25A-LEJS 40 500 A H LEM Series compatible with secondary batteries w e r q t y u i o !
Contact SMC for details. 19 2 Port Oxygen concentrator valve Series DXT474 Diaphragm Valve L type plug connector The DXT474 diaphragm was developed as an operating valve for an oxygen concentrator application for the medical industry, but it can be a valuable solution for applications that requiere a low pressure 2 port valve that has a high reliability and life.