is sufficiently large. 32 100 Caution Handling precautions 50 40 Note 1) When using as a stopper, select a model with a stroke of 50mm or less.
1 Stroke Reading Cylinder with Brake Series CE2 40, 50, 63, 80, 100 RE A B REC CX Brake mechanism added to a stroke reading cylinder which can measure stroke length.
Note) Operating range Note) 8.5 MY1MW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 40 32 25 Mounting position 25 Mounting position 32 40 50 63 25 Mounting position 32 40 50 63 139.5 184.5 229.5 278.5 323.5 A 139.5 184.5 229.5 139.5 184.5 229.5 278.5 323.5 A A 80.5 95.5 110.5 121.5 136.5
B 89 A A B Section BB Coupling P.C.D.
SYA w (B) 2 (A) 4 (A) 4 (B) 2 w y SYJA 1 (P) (EB)3 5(EA) VFA3000 VFA5000 VZA t (A)4 2(B) 3 (EB) 5 (EA) 1 (P) 5 (EA) 3 (EB) 1 (P) VFA VFA r y 1 (P) (EA)5 3(EB) VFRA 2 position double VPA4 Symbol 2 position double SYJA r t q q VFA1000 (B)2 4(A) w w (A) 4 (B) 2 (A) 4 (B) 2 VZA 5(EA) 1 (P) (EB)3 VTA VFA3000 VFA5000 2(B) (A)4 VGA 3 (EB) 5 (EA) 1 (P) 1 (P) 5 (EA) 3 (EB) t r (EA)5 1 (P) 3(EB) VPA
When used without a guide for a light load. When space is very limited. Series REAS Size: 10, 15, 20, 25, 32, 40 Smooth operation is possible through the use of a special slide bearing. To ensure a permanent path. When used for general transporting. A load can be carried directly by the integrated guide type.
Maintain a minimum cylinder separation of 40 mm. (When the allowable separation is indicated for each cylinder series, use the specified value.)
D-Y69l D-Y7P D-Y7PV D-Y7lW D-Y7lWV D-Y7BA D-G5l D-K59 D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-B5l D-B64 D-A9l D-A9lV D-A59W D-F5NT D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5
b) a) b) D-M9 D-M9W D-M9A D-A9 D-M9V D-M9WV D-M9AV D-A9V MK MK MK2T CK1 CLK2 CLKG CKQ CLKQ Auto Switch Proper Mounting Position (mm) Auto Switch Mounting Height (mm) Auto switch model D-M9 D-M9W D-M9AV D-A9V D-M9V D-M9WV D-M9AV CK CLK D-M9A D-A9 D-A9V Bore size (mm) D-M9V D-M9WV CKQ Hs Hs Bore size A B W A B W A B W A B W 4.5 (2) 12 16 19 21 17 19 12 12 4 12 4 4 6 4 12 8 8 0 4.5 (2) 16
HS 40, 50 25, 32 D-A73C D-A80C D-J79C Approx. 30.5 Approx. 26.6 A A A A 25, 32 40, 50 D-A79W D-F7WV D-F7V D-F7BAVL Approx. 30.5 Approx. 22 A A A A 40, 50 D-P5DW Approx. 31 A A Approx.
(mm) Joint A type mounting bracket B type mounting bracket 32, 40 YU-03 YA-03 YB-03 50, 63 YU-05 YA-05 YB-05 RS Allowable eccentricity (mm) M W T2 V 32 40 50 63 Bore size 1 Eccentricity tolerance 0.5 Backlash J E
#1+#5) : RSH Bore size -lll Basic w/locking mechanism w/cancel cap w/lever detection switch w/locking mechanism + cancel cap w/locking mechanism + lever detection switch w/cancel cap + lever detection switch w/locking mechanism+ cancel cap+ lever detection switch Stroke W Bore (mm) R S T U V WB X Y q SRSH Bore size A, #2 (#2+#5) : RSH Bore size -lll-D 50 30 72 40 21 2 5.5 15.5 32 5 10 24
Power cord outlet IDU6D to 15C, IDF6D to 15C IDF75C A 240 240 30 30 240 240 65 65 B 40 40 49 49 40 40 40 40 Model IDU6D IDU8D IDU11C IDU15C IDF6D IDF8D IDF11C IDF15C E 225 225 181 Model IDF37C1 IDF55C IDF75C A 425 190 208 B 375 140 158 C 75 75 66 D 153 153 144 Power cord outlet (17) Grommet with waist Back side Cooling water outlet Cooling water inlet A D E Compressed air pressure gauge B
VQ550 Indicator light Indicator light 214 121.8 195 (200.5) 91.5 59.5 105.8 (Port A) 17.5 13.5 (Port B ) 2 2 73 (78.5) 122 106 59.5 (Port A) 17.5 13.5 (Port B) 2 4 SMC SMC 2 4 A B 40 53 66 162 50 41 37 31.5 18 A B A B 53 66 40 B A 1 3 5 14 12 35 53 2-6.5 Mounting hole Manual override 5 1 3 12 14 Manual override 35 53 2-6.5 Mounting hole G1/2 Electrical entry 18 31.5 37 41 50 98 G1/2 Electrical
B MY CY 22 (20) MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A CX D-A9V D-M9V D-F9WV D-X 20( ): Denotes the values of D-M9V, D-F9WV. 5(7) B W Data D-A9, D-A9V D-F9W, D-M9 D-F9WV, D-M9V Bore size (mm) A A W B W B A W B 6 12.5 3.5 (6) 16.5 7.5 2.5 16.5 5.5 2.5
Symbol A 11.5 12 B 4.5 4 W 19.5 21.5 W 5.5 6 A 11.5 12 B 4.5 4 A 7.5 8 B 0 0 Hs 17 19 W 1.5(4) 2(4.5) A 7.5 8 B 0 0 12 16 Bore size (mm) D-F9BAL Model Symbol Bore size (mm) A 10.5 11 B 3.5 3 W 14.5 15 Hs 17 19 12 16 4.1-13 Rotary Clamp Cylinder/Heavy Duty Series MK2 20, 25, 32, 40, 50, 63 How to Order MK2 B S A73 20 10 R F Number of auto switches Rotary clamp cylinder S 2 1 Mounting Style
depth C 4 x N through 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W G M K J 25 to 40 Minimum lead wire bending radius 10 Auto switch H thread effective depth C 4 x N through F Q 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W E M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A
, 60, 80, 100 A A A A-A r q e w A A-A e r q w Component Parts No.