D-A9, F9 Rod end nut C1 X L1 Rod end male thread (mm) Bore size (mm) C1 X H1 L1 32 20.5 23.5 28.5 M14 x 1.5 40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 (mm) Without auto switch With auto switch A B A B U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43
1 q t i PF2D540 o !0 u !0 !2ywr e !
(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 16 16 16 12 15 15 44 50 56
O-NOT AND output wait command General-purpose input No., State I-AND General-purpose input No., State Input wait OR input wait command I-OR AND input time out jump command General-purpose input No., State (P-No.) label T-AND OR input time out jump command General-purpose input No., State (P-No.) label T-OR Input wait with time out function AND input time out subroutine call command General-purpose
STOP SMC LC5-1-T1 TEACHING BOX TEACH mode Teaching ESC/MODE TEST mode Test I/O mode Does not function with this driver.
port solenoid valve Air filter Ball valve Process pump Process pump Regulator AIR SUP FLUID OUT AIR EXH FLUID IN Air supply By-pass Strainer Silencer Throttle Transfer fluid 4 Series PA3000/5000 Dimensions/Automatically Operated Type PA3000 68 85 105 4-7 7.5 (185) Reset button FLUID OUT Rc 3/8 5.5 AIR SUP (pilot air supply port) Rc 1/4 FLUID OUT PROCESS PUMP AIR SUP 2 115 90 74.5 FLUID I
Use after putting the unit label other than l/min, l. r i SET t y u i Channel display/Red Displays the selected channel. u UP button ( button) Use to change the mode or to increase the set value. SET button Use this button to set the value or the set mode.
Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x
6 i @7 @1 #2 @9 @6 @4 #9 !0 !9 u #0 #6 t #8 q y $0 $1 20 r !1 e @2 !2 #7 #3 #1 32 w 50, 63, 80 @3 Double acting (DL, DM) !3 !5 #6 o @5 @4 i @1 @6 !0 @7 @9 !6 t u !7 !8 q #8 $1 y Single acting spring extended (TL, TM) Double acting spring type (BL, BM) r $0 !1 !
I) Rotate the new drain cock assembly in the direction shown by the arrow below by hand, and tighten it lightly. J) Rotate the lock nut by using a spanner or monkey wrench while lightly holding the internal assembly (chamber head). Tightening torque of the lock nut is 2Nm. H) I) J) Tightening torque 2Nm Tighten lightly.
1 o IN side i Communication cable (With connector on both sides) !0 !2 EX260 Series EX500 Series Specifications Description Communication cable (With connector on one side) Field-wireable connector Terminating resistor Part no. (Cable length) PCA-1557633 PCA-1557646 EX500-AC010-DN (1 m) EX500-AC050-DN (5 m) PCA-1557659 PCA-1557662 PCA-1557675 i o !0 !1 !2 !
Terminal q DC (+) w N.C e DC () r IN (1 to 5 V) e w q Power supply/Output connection cable (Accessory) Power supply/Output connector (8P) Pin no. 7 Green 8 Yellow 6 Red 5 Gray 4 White 3 Black 2 Blue 1 Brown i u y t r e w q Pin no.
VQ1000-FPG-C4M5-D: 6 sets Double check block 757 S0700 Series Construction Body Ported Construction 2(B) (A)4 S0716 2-Position Single r u e w q 3(R2) (R1)5 1 (P) t y i 2-Position Double S0726 2(B) (A)4 r u e w q 3(R2) (R1)5 1 (P) t y i 3-Position Closed Center S0736 r u e w q 2(B) (A)4 (R1)5 1 (P) 3(R2) t y i 4-Position Dual 3-Port Valve S07A6 r u e w q 2(B) 4(A) 5(R1) 3(R2) 1(P) N.C. + N.C
Compact / Lightweight 2 Port Solenoid Valve VDW30/40-XF Series For Air/Water Compact / Lightweight resin body (PPS) IP65 RoHS Weight: 120 g (VDW30-XF) n t r e y l d a i 30 mm c r e i r c e s l t e e c c t b t i Power consumption e e o n d l a n .
Order it separately. 5 52 1 When Without controller/driver is selected for controller/driver types, I/O cable cannot be selected. When the I/O cable is required, order it separately. 2 When Pulse input type is selected for controller/driver types, pulse input usable only with differential.
LOUIS, MO (314) 209-0080 CINCINNATI, OH (859) 647-5600 HOUSTON, TX (713) 460-0762 MILWAUKEE, WI (414) 827-0080 NEWARK, NJ (908) 253-3241 RICHMOND, VA (804) 527-0500 BINGHAMTON, NY (607) 773-1300 TAMPA, FL (813) 243-8350 CLEVELAND, OH (330) 963-2727 ROCHESTER, NY (716) 321-1300 BOSTON, MA (978) 326-3600 TULSA, OK (918) 252-7820 Business Deve lopment Cente r , I n d i a n a p o l i s, I N
port solenoid valve Air filter Ball valve Process pump Process pump Regulator AIR SUP FLUID OUT AIR EXH FLUID IN Air supply By-pass Strainer Silencer Throttle Transfer fluid 4 Series PA3000/5000 Dimensions/Automatically Operated Type PA3000 68 85 105 4-7 7.5 (185) Reset button FLUID OUT Rc 3/8 5.5 AIR SUP (pilot air supply port) Rc 1/4 FLUID OUT PROCESS PUMP AIR SUP 2 115 90 74.5 FLUID I
ZSE ISE PSE Construction Flow Characteristics Z I SE3 Fluid: Water, Outlet pressure: 0 MPa Sealing thread depth: 9 mm (3/4), 11 mm (1) Upper insulator Micro switch PS Flow range (l/min) Retaining screw Flow adjusting screw Mounting Flow switch Z I SE1 2 Minimum Maximum ON-flow rate/setting (m/s) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office