Moment (Nm) Moment (Nm) Load weight (kg) M1 = F1 x L1 Piston speed V (mm/s) M2 = F2 x L2 ML1C/M2, M3 Moment (Nm) M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A. Consider (1) max. load weight, (2) static moment, (3) dynamic moment (when stopper collides) when calculating the max. allowable moment and load weight.
Moment (Nm) Moment (Nm) Moment (Nm) Load mass (kg) M1 = F1 x L1 Piston speed V (mm/s) ML1C/M2, M3 M2 = F2 x L2 M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A. Consider (1) max. load mass, (2) static moment, (3) dynamic moment (when stopper collides) when calculating the max. allowable moment and load mass.
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Symbol None Sealant S Applicable tube O.D.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C HRL Series 3.3 Installation 3-27 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
TYPe d beains 3 tandard s 'qo ' okd ( fYnI ro r r 2.9r 2 3 . 40' I lo , ?
Unit mm/s kg kg kg kg Va W Wa We Wmax K 8
Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.
.: EX500-AP -S Output block connector Connects the solenoid valve, Output block, etc. AUTO: The communication setting is automatically selected. 0 Communication setting Display LED display showing the SI Unit status. These safety instructions are intended to prevent hazardous situations and/or equipment damage.
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
2 131 111 3 177 157 4 223 203 5 269 249 6 315 295 7 361 341 8 407 387 9 453 433 10 499 479 Formula: L1 = 46n + 39, L2 = 46n + 19 4-7-22
(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8
Symbol 46 42.5 Outside diameter Indicator light Max. display pressure Symbol 10 1.0 Unit: MPa Without indicator light Nil L2 Neon light (100 VAC/220 VAC) Attachment (Cover ring assembly) L5 LED/24 VDC Connection thread Without cover ring assembly Symbol Specifications Symbol Size Nil 01 R 1 8 Clear cover has no protrusion. (Clear cover is irremovable.)
TYPe d beains 3 tandard s 'qo ' okd ( fYnI ro r r 2.9r 2 3 . 40' I lo , ?
This is recommended because it can absorb off-centering, compared with direct mounting type. 6.1 16 M 5 Part name Part number P368010-24 Fork lever assembly M N P368010-25 Fork lever assembly S Resin connector (Non-explosion proof specification) L2=31 (M type: 55) 39 (M type: 63) Optional cable connectors are available for different cable sizes.
SETUP I PORTOPORTLOOP SEC mm2/s LABEL PRO Main modes ALM mm/s L C Directs a program operation. RUN Operation mode ACTUATOR & CONSTRUCTION SYSTEM CONTROLLER POWER ALARM STOP Executes a JOG operation.
Contents Action 12 12 CQSB12-S-PS CQSB12-T-PS Kits include items !2, !3 and !4 from the table above. 16 16 CQSB16-S-PS CQSB16-T-PS Kits include item !3 Single acting Spring return Single acting Spring extend 20 20 CQSB20-S-PS CQSB20-T-PS from the table above. 25 25 CQSB25-S-PS CQSB25-T-PS Seal kits consist of item !
DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Slovakia s.r.o. SLOVENIA SMC Slovenia d.o.o.