SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R1Y-5A-2-K-Q"

4.8A 10A 5A 5A 15A 10A 10A 180/200W 50/60Hz 385/440W 50/60Hz 220W 420W 0.01m (99.9%) 6) 2 0.3m3.5/LANR PID / R134a/0.14g R134a/0.26g ()7) 52dB (A) 55dB (A) () 26kg 37kg 10mm 12 CE 1 ANR2065% 2 3 4 0.5 5-5%+10% 6 7 1m1m 6.2 GWP ( G W P) GWP ) Regul at i on ( EU ) N o 517/2014 I PCC AR4 ) R134a 1, 430 1, 430 R404A 3, 922 3, 920 R407C 1, 774 1, 770 R410A 2, 088 2, 090 1 2

Brake disc Manual rod 1 Manual rod 2 Brake spring Air tube Cable Tube guide assembly Guide rod q w e r t y u i o !

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 1 (Bracket)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 6 (600mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 3 (Bracket + Manual Override)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KO (Plug Connector, w/o Connector)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KOZ (Plug Connector, w/o Connector)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: -, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 600mm, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

[White] Blue [Black] Black [White] Load Switch 1 Switch 1 Switch 1 Relay Load Relay contact Blue [Black] Blue [Black] Brown [Red] Brown [Red] Brown [Red] Relay Black [White] Black [White] Blue [Black] Black [White] Switch 2 Switch 2 Switch 2 Blue [Black] Blue [Black] The indicator lights will light up when both switches are turned ON. 2 wire with 2 switch AND connection 2 wire with 2 switch

[White] Blue [Black] Black [White] Load Switch 1 Switch 1 Switch 1 Relay Load Relay contact Blue [Black] Blue [Black] Brown [Red] Brown [Red] Brown [Red] Relay Black [White] Black [White] Blue [Black] Black [White] Switch 2 Switch 2 Switch 2 Blue [Black] Blue [Black] The indicator lights will light up when both switches are turned ON. 2 wire with 2 switch AND connection 2 wire with 2 switch

[White] Blue [Black] Black [White] Load Switch 1 Switch 1 Switch 1 Relay Load Relay contact Blue [Black] Blue [Black] Brown [Red] Brown [Red] Brown [Red] Relay Black [White] Black [White] Blue [Black] Black [White] Switch 2 Switch 2 Switch 2 Blue [Black] Blue [Black] The indicator lights will light up when both switches are turned ON. 2 wire with 2 switch AND connection 2 wire with 2 switch

Flow direction Right Down With element service indicator AMP220 Rc NPT AMP320 AMP420 G 2 Exhaust Cleaner for Clean Rooms Series AMP How to Order AMP 2 0 2 03 Optional specifications Body size None Flow direction RightDown With element service indicator Nil R T 2 3 4 1/4 standard 3/8 standard 1/2 standard Element construction Accessories (optional) Nil None 2 2 stage B With bracket