+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
G H J K L M N P IDF22E R1 775 6001 IDF37E R11/2 855 6801 85 340 (698) (93) 46 25 290 623 (134) (405) 13 314 IDF55E, IDF75E Guige Guige 10 (10, 1m 1m) 4-13 17 (911)[] mm A B C D E F G H J K L M N P Q R IDF55E 800 (868) IDF75E 900 (968) 526 (250) 5195 13 500 75 7001 (455) (110) 36 50 R2 470 855 (128) IDF Series 6-3 6 2 IDX-OM-W026 6 6-4 IDF22E-20, IDF37E-20 IDF22E-30, IDF37E-30 GFCI
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: Rc, Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Stations: 04 (4 Stations), Supply/Return Unit Layout: U (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Viscosity: 3mPas (3cP) or less Detection style Karman vortex Flow rate measuring range 0.4 to 4l/min 1.8 to 20l/min Note 1) 4 to 40l/min Operating pressure range Note 2) 0 to 1MPa 0 to 0.6MPa Proof pressure Note 3) 1.5MPa 0.9MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5%F.S. or less (at 25C water) Repeatability 1%F.S. or less (at 25C water) Temperature characteristics 5%F.S
ARJ 3 10 F BG With One-touch fitting 04 01 Semi-standard Body size Nil 1 S 0.7 MPa setting (Standard) 0.2 MPa setting Note 1) Model Relieving type 10 With seal Note 1) Compared with standard specifications, its adjusting spring has been only changed for 0.2 MPa. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.
6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting
Please contact us for the latest version.sales@ocaire.com, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, FB, AS***F 1/2INCHSTANDARD (PT), .44092 lb, Applicable tubing O.D. (mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 1/2AS4201FG-04-12AS4211FG-04-12AS4301FG-04-12AS4311FG-04-12
(.) 9-2 Ball valve Heavy duty auto drain (ADH4000-04) Drain tube (10) IDFA Series 9-1 9 1 IDX-OM-W032 9 L 9-3 (ADH4000-04) IDFA22E 75E-23-L ) 0.151.6MPa N.O.() 3/h(ANR) ) 3m 9-4 1.
02 03 04 04 06 10 10 12 01 02 01 02 14 20 VEX312VEX322VEX332VEX342VEX350VEX370VEX390( ) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A ( ) VEX1-18-2A VEX3-32-2A P2 AN120-M5 AN103-01 AN210-02 1) VEX1-9-1P VEX4-2A-P VEX1-11-2 VEX4-4 DXT152-14-1A NXT013-3 VO307K-1 2) 3) VEX322 VEX342 Rc A 1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17 VEX4-5 C 1/2 T NPTF 11 No.VEX-OMY0001 (2) () 3 2(A
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 1/2AS4201FG-04-12AS4211FG-04-12AS4301FG-04-12AS4311FG-04-12
Note) Metric size Inch size 23 04 06 08 10 12 Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT Port size AS-FE KE 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 3.2 4 6 8 10 12 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 N AS-FG AS-FG AS-FP AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 542. Use 1/8" tube.