<br>The connection cable for use between the PC and the controller is a dedicated cable. Order an LEC-W2A-C communication cable and an LEC-W2-U USB cable. <br>Note) Connecting using a commercially available cable (LAN cable, etc.) may result in the malfunction of the product.

<br>Whereas for RESET, it decelerates and then stops. This deceleration is the “max. acceleration” value (basic parameter). <br>The servo remains ON after stopping in this case.

<br>Since this Z-phase signal is a signal that is output once per motor, the motor moves about 1 to 2 rotations during this operation. <br>For example, the LEFS25AA is an actuator with a lead of 12 mm, so it moves about 12 to 24 mm during this operation.

<br>If the DRIVE and IN_* signals are input at the same time, since the controller reads the step number from the IN_∗ signal before it has been fully input, the desired movement cannot be performed. <br>Be sure to set DRIVE to ON at least 15 ms after inputting the IN_∗ signal.

<br>The ZB series catalog can be found here. <br>These vacuum ejectors were designed with a focus on increasing suction speed and reducing product size and weight for mounting on moving parts to allow for the high-speed suction and transfer of handlers, chip mounters, etc.