Possible to use in vacuum to 100 kPa Applicable Tubing Tubing material FEP, PFA, Nylon, Soft nylon, Polyurethane Tubing O.D. 4, 6, 8, 10, 12, 16 Specifications Fluid Air, Water 1 Operating pressure range 2 100 kPa to 1 MPa Proof pressure (at 23C) 3 MPa Ambient and fluid temperature 5 to 60C, Water: 0 to 40C (No freezing) Thread Mounting section JIS B 0203 (Taper thread for piping) JIS B 0205

L n 2 5 6 7 8 9 10 4 3 Internal Pilot Manifold L Dimension n: Stations L n 2 5 6 7 8 9 10 4 3 External Pilot Manifold L Dimension n: Stations L1 L2 L3 L4 L1 L2 L3 L4 98 87.5 70 14 110.5 100 80.5 15 123 112.5 91 16 135.5 125 101.5 17 135.5 125 112 12 148 137.5 122.5 13 160.5 150 133 14 173 162.5 143.5 15 185.5 175 154 16 110.5 100 80.5 15 123 112.5 91 16 135.5 125 101.5 17 135.5 125 112 12

100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)

auto shift input (Brown) DC (+) 1.2K (Brown) DC (+) (Gray) Analog output (Gray) Auto shift input Main circuit Main circuit Main circuit Main circuit Load Load 1k 12VDC to 24VDC Load Load 6.8K 12VDC to 24VDC (Black) OUT 1 (Black) OUT 1 (White) OUT 2 (White) OUT 2 (Blue) DC () (Blue) DC () ZSE F/ISE --62(L)-(M) 50 60 50 60 ZSE F/ISE --70(L)-(M) 50 60 50 60 With analog output With auto shift

How to Order Pilot Valve Assembly 1 G 00 VT3112 Rated voltage Electrical entry Note) 1 100 VAC, 50/60 Hz Grommet G 2 200 VAC, 50/60 Hz Note) Even if the electrical entry of the solenoid valve is T, D, TL, or DL, the electrical entry for pilot valve assembly is chosen for G. 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-6-1 2 Series VP450

81.5 83.5 2-M6 X 1 X Depth 9 1 2 3 4 60 143.5 62.5 156.5 36.5 16.5 20 Center 116.5 70 25 VEX5700 VEX5701 1 4 1 4 160.5 150.5 62.5 90 60 30 15 7 173.5 37.5 100 13 88.5 86.5 18 4-M6 X 1 X Depth 6 136.5 60 17 82 c Bracket mounting dimensions g Grommet h Grommet terminal i Conduit terminal j DIN connector a Model b d e f VEX5500 VEX5501 19 130 110 9 12 2.3 187 187.5 205.5 205 32 VEX5700 VEX5701

See Specific Product Precautions. 0.2 GD 0 0 10 20 30 40 50 Operating temperature (C) Port size Model Rated flow (L/min (ANR)) Note 1) Weight 60 80 100 100 100 100 300 400 500 500 35 g 35 g 35 g 35 g 60 g 150 g 190 g 190 g 190 g 260 g 4 (One-touch fittings) 6 (One-touch fittings) 8 (One-touch fittings) Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 8 (One-touch fittings) 10 (One-touch fittings

T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) 50 Main

Models suitable to satisfy the requirement of 100 (N) are CY332 or CY340. 300 100 200 50 100 20 30 40 50 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10111213 7 8 9 1 01 11 21 3 1 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B25 500 300 200 100 20 30 40 50 10 Useable range 5 1 0 1 2 3 4 5 6 7 8 9 10111213 Distance

Models suitable to satisfy the requirement of 100 (N) are CY332 or CY340. 300 100 200 50 100 20 30 40 50 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10111213 7 8 9 1 01 11 21 3 1 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3B25 500 300 200 100 20 30 40 50 10 Useable range 5 1 0 1 2 3 4 5 6 7 8 9 10111213 Distance

Allowable kinetic energy (Graph (1)) Extension locking Retraction locking 100 100 63 Load weight kg Load weight kg 63 50 50 40 40 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10 32 32 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 1 1 100 500 Maximum speed mm/s 100 500 Maximum

Cylinder ports should be NAMUR hole pattern. 100/200 V (50/60 Hz) 24 V 15 to +10% of rated voltage Class B or equivalent 5.0 VA/60 Hz, 5.6 VA/50 Hz 2.3 VA (1.5 W)/60 Hz, 3.4 VA (2.1 W) 9/50 Hz 1.8 W Grommet, Grommet terminal, Conduit terminal, DIN terminal Note 1) Use dry-air at low temperature. Note 2) Use turbine oil Class1 (ISO VG32), if lubricated.

D-M5NT D-M5PT Auto switch model 3 m (L) 60 Lead wire length 5 m (Z) 95 Ex.) Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet y A Connection thread S 10 94 60 23 20 132 70 51 30 142 80 40 178 90 77 50 188 100 E D C B 10 49 32.9 24 P 10 8 M5 x 04 06 2.5 Applicable tubing O.D.

(s3) 6.69 (170) 2.O5 (.521 2.da (66) (r78) 1.57 (40) 402 (102) 3.07 {78) 0.98 (25) 2.05 (52) 0.55 ( 1 4 ) 3.94 {100) 1.50 (38) \62) 1.34 (35) o.67 ( 7 ) M22x1.5 (3?)

Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000

(mm) Model CXS25-10 S SS ZZ Z 10 94 118 30 20 104 128 40 30 114 138 40 40 124 148 40 21-/2210-/11-/12CXS25-20 CXS25-30 CXS25-40 CXS25-50 21-/2210-/11-/1221-/2210-/11-/1221-/2210-/11-/1250 134 158 60 21-/2210-/11-/12100 184 208 80 CXS25-75 CXS25-100 21-/2210-/11-/1275 159 183 60 21-/2210-/11-/1286 Dual rod cylinder CXSL 1221CXS / 10-/1122Basic style / CXS32, CXSL32 10-/11221221Air cylinder

MI W S 100 200 50 CEP1 130 50 100 50 40 40 CE1 40 Weight of transferred object m (kg) Weight of transferred object m (kg) 32 30 40 50 CE2 20 30 32 20 ML2B 20 16 10 C J G5-S 10 12 5 4 CV 3 4 5 3 MVGQ 2 2 CC 1 1 RB 1 5 10 20 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) J Lateral Load and Operating Pressure DThe larger the lateral load, the higher the operating pressure required

Mounting bolt M5 X 115 with SW M5 X 35 with SW M5 X 15 with SW M5 X 45 with SW M5 X 60 with SW M5 X 65 with SW M5 X 70 with SW M5 X 75 with SW M5 X 90 with SW M5 X 95 with SW M5 X 100 with SW M5 X 105 with SW Size SMC SMC SMC SMC SMC Option mounting diagram SMC SMC SMC SMC Spacer 2 SMC Spacer 2 Interface regulator Spacer 1 Throttle valve spacer SMC Release valve spacer Spacer 2 Spacer 1 Spacer

VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other VY1 G Option D: Type D DIN terminal Nil G None PPA With pressure gauge AL How to Order Pilot Valve Assembly SF4 1 G 80 Y: Type Y DIN terminal Rated coil voltage 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 to 120 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other Soft start-up