54.8 21.9 1.2 49.3 123 AS320-N03-SD NPT 3/8 NPT 3/8 AS320-F03-SD G 3/8 AS320-03-SD Rc 3/8 19 22.5 R 3/8 24.3 9.8 30 52.6 19.7 1.2 47.4 128 AS420-N04-SD NPT 1/2 23.8 NPT 1/2 AS420-F04-SD G 1/2 AS420-04-SD Rc 1/2 24 27.5 R 1/2 28.5 12.4 38.5 62.9 25.8 1.2 55.8 222 Reference thread dimensions after installation. 751
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port
S VNB F U D E SGC Bracket (Option) A B 15 SGH VNC 1(A) (Back side 2(B)) Main port T C Port size: refer to table below A B VNH VND VND Main port 1(A), 2(B) A B C D E F G M N P Q R S T U Model VCC VND20D-10A VND20D-15A VND30D-20A VND40D-25A 3 8 1 2 3 4 1 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 TQ 80 90 50 60 35 44 17.5 22 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30
35 38 30 40 50 56 37 43 50.5 58.5 75 100 126 141 88 118 148 163 36 44.4 57.7 66.4 10.5 16 19.5 15.5 62 6 x 8 7 x 10 9 x 12 9 x 12 TQ 70 92 109 631 A VNH Series Specific Product Precautions Be sure to read this before handling the products.
Measurement conditions: Fluid temperature 183C, Ambient temperature 60C Temperature of the fitting port of the insulated adapter: Mounted 70C Not mounted 130C Connection thread Proper tightening torque [Nm] M5 (Insulated adapter) 0.4 to 0.6 Rc1/8 7 to 9 Rc3/8 22 to 24 Rc1/2 28 to 30 Rc3/4 4.
Series ZSE48/ISE4DB (mm) Dimensions Standard Type 4 M4X07 20 30 25 5 6 8 5 / dePlh 5.5 I ~i" ~1 I I I .. -# I f-ri: ~ It: ~\I I II 0 '" !~ \'\1 ~/I I~ j 'l OI :A(PT)Y. T1 NPTF Ya PipIng port / I M5XO 8 "eplh 5/ I 8 ~~ With Bracket A I 30 ~ o ~ I I ::1 ';!1 rl .J '1'1..
1 sheath} Argon 0 SUS630 Pressure sensor Nitrogen gas 0 Firtil1Qs SU$304 Chlorine gas X 2 Digital pressure switch for general purpose fluid Series Z5E5/15E5 Dimensions (mm) Scale: 75% 30 39 LCD With back light g '" .; ~ '" '" DOWN button UP bulton ~ .{ LED (red) I SET button T2 NPTF'4 M5X O 8 deplh 5 I 12.3 20 4 .0' 2.7 17 depth 6.5 i 28 View A With bracket 50 (44) 4.%4S 40 30 39 II i
Weight (g) L1 M Width across flats H1 H2 Nozzle size D Model KN-04-100 KN-04-150 KN-06-100 KN-06-150 KN-06-200 KN-08-150 KN-08-200 KN-10-250 KN-10-300 KN-10-350 KN-10-400 KN-10-600 KN-12-350 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN-20-600 13 14 19 20 22 28 30 35 36 37 30 28 54 55 40 77 79 117 112 15 15 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 27 27.7 30.1 30.8 31.5 33.8
M16 x 2 Thread depth 30 280 145 140 273 210 80 120 130 78 78 130 20 5 20 4B Weight (kg) S T U V W X Model Threaded without flange With flange FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 23 M8 x 1.25 Thread depth 8 35 6 84 180 2.4 3.4 28 35 M8 x 1.25 Thread depth 8 50 8 91 240 3.6 5.0 44 50 M8 x 1.25 Thread depth 9 62 10 103 300 5.4 7.8 62 77
Provide about 30 cm of space above and below the D.P. Lube or the D.P. Lube Unit to facilitate their maintenance and inspection. 2. When the line is stopped, do not adjust or set the differenital pressure, as it could cause the differential adjustment valve to break. 3.
, parity, number of data bits, etc.) or very short message intervals from customer equipment. 0(*3) Bad wiring or no message sent from customer equipment. (1) CRC(Refer to 3.10.2), LRC(Refer to 3.10.1). (2) XX means that it is undefined. (3) After the outgoing message is received from the customer, and displays it in case the message is a state that can not be received was continued for 30
In the actual setting, adjust them after confirming the auto switch operating condition. 30 - Maintenance and Inspection For most suitable use of rotary table, regular inspection is required according to the operating condition.
2 13 3. 3. 3. 3. 3-1. ,,,2 2 3-2. 2 2 2 32 40 VF3000 VZ3000 AS2000 6/4 14 4. 4. 4. 4. 4-1. , ,, ,4.1 , ,4.1 ,,, 4.1 4.1 [N] 5 10 15 20 25 30 40 50 75 100 32 14 13 13 13 13 13 12 11 10 9 40 23 22 22 21 21 21 19 18 16 15 , , , 4.24.34.2, 15 4.2 4.2 [N] [MPa] [mm 2] 0.15 0.2 0.3 0.4 0.5 0.6 0.7 [mm] OUT 804 121 161 241 322 402 482 536 32 12.2 IN 675 101 135 202 270 337
. #2 #2 3 8 Typ. 1 4 Typ. 30 4-28 RLT 2-1 4-28 RLT 2-3 4-28 LT 2 1/2 4-28 LT2 4-28L T1 Tees: 1/4-28 Male to Tube Fibre Gasket Supplied Note: Also available as Reducing Tee combinations similar to the example below 3 8 1 2 31/32 3/4 #4 #2 1 11/16 3/4 3/4 17 32 Typ. 5/16 Hex Typ. 31 4-28 RT 4-2 4-28 T2 1/2 4-28 T2 4-28 T4 4-28 T3 4-28 T1 4-28 T5 Page 7 Distributed by Power Aire, Inc.
, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.
For details, refer to the WEB catalog or Best Pneumatics No. 3. 15-E649 Series MGP Series MGP Dimensions: 12 to 100 With Flange MGPF Flange FC FD H G FF FE 4 x FG through B + Stroke C + Stroke FB FA FH [mm] Bore size B C FA FB FC FD FE FF FG FH G H 12 42 29 7 6 80 89 18 25 4.5 5 26 58 16 46 33 7 6 88 98 22 32 5.5 5 30 64 20 53 37 8 8 102 112 24 38 5.5 6 36 83 25 53.5 37.5 9 7 114 126 30
Arm opening angle 30, 45, 60, 90, 105, 120, 135 Switch TURCK/P&F Both TURCK and P&F switches are available. Port thread NPT/G Reduces the effects of impact from unclamping the cylinder. Arm Variation Prevents the infiltration of spatter, dust and other contaminants.
9.5 24.3 19 22.5 AS320-N03-ST NPT 3/8 NPT 3/8 AS320-F03-ST G 3/8 AS320-03-ST Rc 3/8 R 3/8 47.4 1.5 20.8 53.7 30 9.5 24.3 19 22.5 AS420-N04-ST NPT 1/2 NPT 1/2 AS420-F04-ST G 1/2 AS420-04-ST Rc 1/2 R 1/2 24 27.5 55.8 1.5 26.7 63.8 38.5 12 28.5 23.8 Reference thread dimensions after installation. 15-9-106
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time.
50 70 100 .001 10 30 50 70 100 Q (l/min) Q (l/min) Filtration Efficiency (Initial Value) Fluid: Potable water Flow rate: 20l/min Liquid temperature: Room temperature Test dust: AC course Amount of dust: 0.2mg/min Test method: Per P/A test method (sanitary test stand, HIAC particle counter) 100 100 ) m ) ) m m 0 ) 0 m (2 (2 (5 (5 20 20 05 05 -0 S0 S0 S0 0S 00080 N-1 N-1 80 N-1 -1 1N 101