SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-06-M3"

(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit

(except IDG1, IDG5) Maintenance Part Lists PA3000/Automatically operated type PA5000/Automatically operated type PAX1000 KT-PA5-31 KT-PA3-31 KT-PAX1-31 Diaphragm kit (PTFE) Diaphragm kit (PTFE) Diaphragm kit (PTFE) KT-PA5-32 KT-PA3-32 KT-PAX1-36 Check valve kit Diaphragm kit (NBR) Diaphragm kit (NBR) KT-PA5-36 KT-PA3-36 KT-PAX1-37 Check valve kit Check valve kit Switching valve parts kit

38 31 40 28.5 25.5 31.5 25.5 34 25.5 36.5 27.5 38.5 27.5 71.5 27.5 81.5 27.5 29.5 26 30 26 39 25.5 42 33 50 33.5 31 36 31 38.5 31 41 34 43.5 34.5 77 87 33.5 31 34.5 31 43 31 46.5 39 63 38.5 36 40.5 36 43 36 46 39 48.5 39.5 83.5 93.5 39 36 40 36 48 36 51.5 44 80 46.5 45 49 45 52 45 52.5 46.5 55 46.5 92.5 103 47.5 45 48.5 45 56.5 45 58 51.5 100 54 53.5 57 53.5 59.5 53.5 59.5 55 62 55

, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.

31 31 36 Y 20 20 20 23 Z 8 8 8 10 LD 4 4 4 4 LT LS 25 28 28 30 Bore size 40 47 47 54 13 17 17 22 26 32 32 41 26 26 26 31 41 45 45 50 5 6 6 8 8 8 8 10 21 25 25 27 149 153 155 191 The bracket is shipped together.

Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006

Description Replacement parts Tubing outside diameter Metric sizes Inch sizes Body class Type LQ-GP J 3 03 03 4 04 04 04 04 6 06 06 06 8 08 10 10 10 12 12 12 19 19 19 25 25 1/8" 03 03 03 03 3/16" 05 05 1/4" 07 07 07 3/8" 11 11 1/2" 13 13 3/4" 19 19 1" 25 Insert pin holder assembly (with the parts case) Type Insert pin/ Holder type 1 2 1 2 3 4 5 6 J Insert pin material (J/K type

ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E Body size 1 KE AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.

106.5 40 13.5 36.5 61.5 86.5 111.5 136.5 D-H7l D-H7C D-H7lW D-H7BA D-H7NF D-A9l(V) 20 6.5 30 55 80 25 5.5 30.5 55.5 80.5 32 7 31 56 81 106 40 13 36 61 86 111 136 20 3 26.5 51.5 76.5 25 2 27 52 77 32 3.5 27.5 52.5 77.5 102.5 40 9.5 32.5 57.5 81.5 107.5 132.5 D-G5NT 20 1.5 25 50 75 25 0.5 25.5 50.5 75.5 32 2 26 51 76 101 40 8 31 56 81 106 131 D-C7l D-C80 D-C73C D-C80C D-B5l

This produuct Your system Circulating fluid temperature 31 Serial communication Discharge temperature 31 Circulating fluid display temperature Heat 31 radiation 1 Circulating fluid set temperature 30 Offset temperature 30 1 HRL Series 5.4 Description of Screen 5-29 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Example of MODE 2 When the offset temperature is -1oC, circulating

-150 KNL3-06-200 KNL6-06-150 KNL6-06-200 1.5 2 1.5 2 6 6 6 6 300 300 600 600 D L1 Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection with the blow gun.

Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39

) AS32l1FG-02-06(S)A 6 1/4 17 (17.5) 13 13.3 40 (40) AS32l1FG-02-08(S)A 8 13.2 22.7 33 14.2 41 (41) AS32l1FG-02-10(S)A 10 15.9 26.7 37 35.7 15.6 42 (42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S)A 6 10.4 21.8 32.1 36.4 50 48.4 44.5 42.9 1/4 19 16.6 13.3 29 (30) AS32l1FG-03-08(S)A 8 13.2 22.7 33 14.2 AS32l1FG-03-10(S)A 10 15.9 26.7 37 28 15.6 30 (31) AS32l1FG-03-12

ON OFF Output Maintenance signal Requirement for maintenance detected ON OFF Input External switch signal 1, 2 16 IZN10E Series Dimensions Energy saving static neutralization nozzle IZN10E-01m 06 07 High flow rate nozzle IZN10E-02m 06 07 18.31 (100) 2.5 16 5 92.5 46 3.5 L 6 18.5 6 11 8 L 12.4 5 6 M3 x 0.5 thread depth 4 (Ground terminal) 40 27.7 L-L Applicable tubing O.D. d A 86.4 [mm] Model

This produuct Your system Circulating fluid temperature 31 Serial communication Discharge temperature 31 Circulating fluid display temperature Heat 31 radiation 1 Circulating fluid set temperature 30 Offset temperature 30 1 5.4 Description of the Screen HRL Series 5-30 HRX-OM-X037 Chapter 5 Display and Setting of Various Functions Example of MODE 2 When the offset temperature is -1oC, circulating

Applicable air preparation equipment VHS20 VHS30 VHS40 VHS40-06 VHS50 Y200-A Y300-A Y400-A Y500-A Y600-A AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Note) VHS50 can be connected to AC55 and AC60.

Model VEX55 04 06 10 Description VEX5710 12 VEX5914 20 Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Pressure gauge 5.1-27 How to Order How to Order Pilot valve 1 06 2 E Z 5 1 B VEX5 SF4 20 B Bracket Option Electrical entry Economy valve Coil rated voltage G Pressure gauge (Ex.)

31 31 31 : 3 position ( ): Rc3/8 1.11-7

M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 M3 M3, M4 M3, M4 M3, M4, M5 M4, M5, M6 MSQ MRQ Symbol: A4 Symbol: A5 Symbol: A3 The long shaft can be further shortened by machining it into a stepped round shaft. (If shortening the shaft is not required, indicate for dimension X.) (If not specifying dimension C1, indicate instead.)