Tightening of M3 and M5 screws 1) M3 1. After tightening by hand, the barb fitting type should be tightened by an additional 1/4 rotation using an appropriate wrench. 2. After tightening by hand, the barb elbow type should be tightened by an additional 1/2 rotation using an appropriate wrench. 2) M5 1.

(Tolerance 30%) Dimensions Bore size (mm) Z Auto switch part number H H' HW C T T' D-G39C-4, D-K39C-4 D-G39C-5, D-K39C-5 D-G39C-6, D-K39C-6 D-G39C-8, D-K39C-8 D-G39C-10, D-K39C-10 40 50 63 80 100 57 58 60.5 64 67 69 77 91 107 121 44 52 64 78 92 49.5 50.5 52 53.5 56.5 7.5 8.5 10.5 12.5 15.5 6.5 6.5 7.5 9.5 9.5 M5 X 0.8 X 16 M5 X 0.8 X 20 M5 X 0.8 X 25 5.3-38 Solid State Switch/Direct Mounting

kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE OUT OUT OUT OUT OUT SET SET SET SET SET With One-touch fitting (4, 6, 5/32", 1/4") Reduced dimensions in piping direction 17.8 mm reduction Straight type 12.4 mm reduction Elbow type 14.4 22.4 12.4 mm 17.8 mm 32.2 34.8 KQ2H06-M5 KQ2L06-M5 Comparison when One-touch fittings (KQ2H06-M5 / KQ2L06-M5) are connected to the piping

36.5 13.5 15 32 25 23 M5 24 59 46 57 60 54.5 48.5 101 57 68 1/2 22 45 89 41 11 17 36 22.5 23 M5 26 64.5 48 62.5 62 60 50.5 103 62.5 70 1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)

Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15

. +0.07 0 IH2-03B IH2-04B IH2-05B IH2-06B IH2-08B IH2-10B IH2-03B IH2-05C IH2-06C IH2-06B IH2-10C 25 16 76 60 25 32 M16 x 1.5 26 M5 x 0.8 16 CHQ +0.07 0 25 16 76 60 25 32 M20 x 1.5 31 M5 x 0.8 16 F J E +0.084 0 31.5 20 90 70 30 40 M24 x 1.5 36 M5 x 0.8 20 dH10 CHK B-series +0.1 0 40 31.5 145 115 45 60 M30 x 1.5 50 M6 x 1.0 30 +0.1 0 40 31.5 145 115 45 60 M39 x 1.5 61 M6 x 1.0 30 CHN H 0.1

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 97 8.5 115 118 Purge air for dehumidification 5 M5 x 0.8 Drain Drain (Maintenance space 100 mm or more) 5.5 M5 x 0.8 With fittings for purge air discharge (Option: P) Purge air discharge tubing port for dew point indicator Applicable tubing O.D.: 8 Port

Screw-in Piping M5 X 0.8 Relieving port size 50 to 500mm/s Piston speed Mounting Basic, Axial foot, Front flange, Rear flange *Auto switch attachable Dimensions REC B/Basic H2 2-Rc(PT)P Width across flats B2 2-NN G G H1 Width across flats B1 Relieving port M5 X 0.8 Standard port I Relieving port 2-Eh8 D MM AL K A N N F lNA S+Stroke H F ZZ+Stroke (mm) A AL B1 B2 D E F G H H1 H2 I K MM N NA

Nominal thread size Applicable bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Symbol Applicable cylinder nominal thread size M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 Symbol 10 16 20 32 40 63 4-070 5-080 8-125 10-125 14-150 18-150 Mounting Warning 1. For the screw-in depth of the female threads, refer to the dimensions (page 10-19-14). 2.

Air cushion Cushion Screw-in type Piping M5 x 0.8 Relief port size 50 to 400 mm/s Piston speed Mounting Basic style, Axial foot style, Rod side flange style Head side flange style Auto switch can be mounted.

A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,

Nominal thread size Applicable bore size (mm) 10 10, 16 20 25, 32 40 50, 63 Symbol Applicable cylinder nominal thread size M4 x 0.7 M5 x 0.8 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 Symbol 10 16 20 32 40 63 4-070 5-080 8-125 10-125 14-150 18-150 Mounting Warning 1. For the screw-in depth of the female threads, refer to the dimensions (page 10-19-14). 2.

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.

Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3

A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,

Action D B T Port thread type Double acting Double acting with spring loaded Single acting (Spring extend) 20 to 50 Nil TN TF Rc NPT G Note) TF for 20 indicates M5.

x 0.8 16 5.2 25 15.5 69 15 6 25 42.5 25, 50, 75, 100, 125, 150, 175, 200 106 M8 x 1.25 10 8 28 25.5 78 15.5 10 36 53.5 Q R T V Y N O P Bore size (mm) 12 20 47 7 53.5 22 7 M4 x 0.7 M5 x 0.8 50 15 62.5 36 5 5.5 M6 x 1 M5 x 0.8 Refer to page 11 regarding the rod end nut which is included.

With Air Cushion/Basic: CLG1BA Bore (mm) Stroke range A B1 BC BN BZ C D E GA GB GC GD GK GL GQ GR I J K KA MM NA AL 20 25 32 40 to 200 to 300 to 300 to 300 15.5 19.5 19.5 27 18 22 22 30 13 17 17 19 57.5 69 69 76 8 10 12 16 M4 X 0.7 depth 7 M5 X 0.8 depth 5 M5 X 0.8 depth 8 M6 X 1 depth 12 5 5.5 5.5 6 10 14 24 29 35.5 44 12 14 18 25 14 16.5 20 26 38 45 45 52 M8 X 1.25 M10 X 1.25 M10 X 1.25

ASN How to Order AQ ASN2 03 ASV JIS Symbol AK Option Nil S None With seal ASS Port size ASR M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASF Thread type Metric thread (M5) Unified thread (10-32 UNF) R NPT Nil N Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Number of needle rotations 15-11-1 2 Series ASN Construction Component