Terminating resistance FG FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + + 1 1 1 2 2 2 9 9 9 SG 5 SG 5 SG 5 SG Internal connection Internal connection Internal connection Pin No. Symbol Pin No. Symbol Pin No.
Description Material NBR 63271 63271 63271 3 pcs. 63271 3 pcs. 63271 5 pcs. Element r Packing e 63148 63148 63148 3 pcs. 63148 3 pcs. 63148 5 pcs. Drain NBR O.D. 112 x I.D.90 x T3 1 pc. O.D.112 x I.D.90 O.D.112 x I.D.90 x T3 3 pcs. x T3 5 pcs. t Packing V#6500 AL-61S AL-60S y Gasket AL-62S AL63S 3 pcs. AL-31S JIS B 2401G35 5 pcs. u O-ring NBR JIS B 2401G35 1 pc. JIS B 2401G35 1 pc.
Model CCVS CCVL -X Bore size (mm) Intermediate stop accuracy of CCVS: 50 mm/s x 0.015 sec. = 0.75 mm in case of 50 mm/s Fig. (5) Technical Data 1167 Air-hydro Unit CC Series How to Order The air-hydro unit consists of a converter and a valve unit that are compactly integrated.
O.D.112 X I.D.90 X T3 5 pcs. Packing NBR O.D.112 X I.D.90 X T3 1 pc. O.D.112 X I.D.90 X T3 3 pcs. t V#6500 O.D.268 X I .D.225 X T3 1 pc. O.D.218 X I.D.175 X T3 1 pc. Gasket AL-62S AL63S 3 pcs. AL-31S y JIS B2401G35 5 pcs. O ring JIS B2401G35 1 pc. JIS B2401G35 3 pcs. JIS B2401G35 3 pcs.
10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.
Orifice size (mm) 2 3 4 5 7 10 Symbol 2 3 4 5 7 10 Class 3 Class 2 Class 4 Electrical entry G Grommet C Conduit Refer to the table below for orifice and port size combinations.
Current and Operating Max. 50mA 5-40m4 5 -40mA N4ax.50rnA Max. 40mA l\4ax.20mA D-R8 D-57 N4ax.40mA 150mA T? . Operating lemp (5 60'c) . Length of lead wire 0.5m (slandard) . Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And.
Current and Operating Max. 50mA 5-40m4 5 -40mA N4ax.50rnA Max. 40mA l\4ax.20mA D-R8 D-57 N4ax.40mA 150mA T? . Operating lemp (5 60'c) . Length of lead wire 0.5m (slandard) . Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And.
Numeric data Read or written data with 5 digits regardless of its type. Minus data: (symbol for minus) is displayed at the 1st digit Position of decimal point: Not included in 5 digit data. Ex) The 5 digit numeric data means Ex.
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: C4 (ø4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)