= 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) D-F5mW D-J59W D-F5BAL D-F59F 120 150 2 (Different surfaces), 1 15 120 135 140 (n 2) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 (n 4) 2 15 + 55 120 + 55 150 + 55 120 + 55 135 + 55 140 + 55 n (n = 2, 4, 6, 8) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) (n = 4, 8, 12, 16) 130 160 2 (Different
Do not apply excessive lateral load to the piston rod.
Caution Tubing size Tensile force of tubing (1) Be certain to wear safety glasses at all times 6 12 during periodical inspections. (2) Replace fittings or tubing having the 8 20 following problems. a) Cracks, gouges, wearing, corrosion b) Air leakage c) Twists or crushing of tubing d) Hardening, deterioration or softening of tubing 10 30 12 35 (3) When replacing tubes or fittings, do
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Stations 1 2 3 4 5 6 7 8 9 M SMC 56 28 AXT100-DR-8 110.5 AXT100-DR-10 135.5 SMC SMC K K P P C C U U O O S S L L H H AXT100-DR-12 160.5 11.5 8 AXT100-DR-14 185.5 12 12 3 AXT100-DR-16 210.5 AXT100-DR-19 248 AXT100-DR-21 273 AXT100-DR-23 298 81 16 AXT100-DR-25 323 AXT100-DR-28 360.5 33.5 14 OUT IN OUT IN ARM11BC2-08 Knob position: Bottom L2 L2-10.5 L1=(28 x n)+36 18 28 52.5 39 28 12 12 5.3 3
Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling.
Please consult with SMC for details. (1) Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. (2) Do not use in explosive atmospheres. (3) Do not use in locations subject to vibration or impact. (4) Do not use in areas where product is exposed to heat sources or in areas where the product is exposed to radiant heat. (5) Employ suitable protective
Do not introduce oil in lubricated air as this may reduce locking performance significantly. 7-2.
Name Material Remarks 1 Body Stainless steel 2 Spool Special stainless steel 3 Sleeve Special stainless steel 4 Plate Aluminium 5 O-ring H-NBR 6 Retaining ring Carbon steel 7 Retaining ring Carbon steel 8 Radial bearing MQR2 to 12-M5 Components / (MQR2 to 12 M5, 2 to 12 circuits) No.
state auto switch 2-wire 12 V M9BV M9B M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V,12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V,12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (
) 12 No.VP3145-OMM0002-B Countermeasure No.
KAR08-12 42 4.6 12 10 KAR10-12 44.5 33 32.8 32.8 12 20 21 18.5 15-3-24 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
Port size(R) 12 Max. Operating Pressure (MPa) 0.7 Max. Operating temp.
A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12
Operating environment Do not allow corrosive fluids or solvents, etc., to come into contact with the outer surfaces of the pump. Do not use in water (or other liquid). Fluid may leak into the pilot switching valve and there may be corrosion of external parts, etc. 2. Low temperature operation Do not allow freezing.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate or set with wet hands. This may lead to an electric shock. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Solenoid valve side pin wiring diagram Since voltage specifications other than standard 24 and 12 VDC do not have diodes for polarity protection, be careful not to make errors in the polarity. When wiring is done at the factory, positive (+) is red and negative () is black.
Note There are two types of bodies, which are 12-2 and 12-3 described above according to the model. Please note that the applicable model cannot be changed by switching these two types of products.
Disassembly Drawing of the Pressure Gauge Port [Applicable model: without pressure gauge / with pressure gauge (round type)] (12) Plug assembly (12) Plug assembly (3) Pressure gauge (round type) Micro mist separator regulator 12-3.
CJ-CF006 CJ-CR006 M3 x 0.5 6 6 8 11 8 5 6 10 CJ-T010B CJ-CF010 CJ-CR010 3.3 M4 x 0.7 10 8 10 13 10 6 8 29 2 9 4.5 3.1 18 40 22 32 12 8 +0.048 0 16 CJ-T016B CJ-CF016 CJ-CR016 5 M5 x 0.8 16 10 12 15 7 12 10 35 14 5.5 6.4 2.3 20 48 28 38 16 10 +0.048 0 6-3-11 12 12 Series CJ2 Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height Auto switch Solid state switch