cartridge) 6 6 5 5 Discharge time (s) Discharge time (s) 4 4 30 Hz 1 Hz 30 Hz 3 3 1 Hz 2 2 1 1 Sensing AC Sensing AC 0 0 2,000 0 500 1,000 1,500 0 500 1,000 1,500 2,000 Installation distance (mm) Installation distance (mm) 418 Technical Data IZS40/41/42 Series IZS IZS IZS42 1) Without air purge IZN 0 2 4 6 8 10 12 14 16 18 20 IZF 1 Hz 30 Hz Discharge time (s) ZVB IZD IZE IZH 0 50 100 150
Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007
How to order Accessories NIL: None Port size Note B: With Bracket (130184) G: With Pressure gauge 02 : Rc1/4 IW212:G51-2-02 IW213:G51-4-02 IW215:G51-7-02 NoteOnly one size Setting pressure 2: 0.02~0.2MPa 3: 0.02~0.3MPa 5: 0.02~0.5MPa -6- 4.
5 #6 q t #8 !4 !7 @2 @3 @4 r y e #7 u o !1 i w !8 #4 !6 A @0 @1 !9 #2 !0 #1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A Ball bushing bearing #5 @5 #0 @6 @8 !7 !3 #8 !2 @1 !
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
SOL.A 1 station 2 stations 3 stations 4 stations 1 () SOL.A 14 () SOL.A 2 () 1 SOL.A 14 15 () 2 SOL.A 15 3 () 3 4 5 6 7 8 9 10 11 12 13 5 stations 16 17 18 19 20 21 22 23 24 25 SOL.B 16 () SOL.A 4 () 6 stations SOL.B 17 () SOL.A 5 () 7 stations SOL.B 18 () SOL.A 6 () 8 stations SOL.B 19 () COM. 13 (+) Connector terminal no.
(Including bracket, screw) CLS Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 CLQ Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) RS Q G Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 RS H A Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
5 #6 q t #8 !4 !7 @2 @3 @4 r y e #7 u o !1 i w !8 #4 !6 A #2 !0 !9 @0 @1 #1 A' Ball bushing bearing #5 @5 #0 @8 !7 @6 !3 #8 !2 @1 !0 @9 Slide bearing y Long stroke 100 @7 80, 100 View A-A Component Parts Component Parts Description No. Description No.
None Supply valve (1) (1) (2) (2) Release valve (4) Supply valve (1) (1) (2) (2) Release valve (4) Supply valve (1) (1) Release valve (4) Supply valve (1) (1) Release valve (4) Supply valve (3) (3) Release valve (4) K1 J1 Q1 Q2 VQ110 Rated voltage (4) ZB1 (4) (4) 5 6 24 VDC 12 VDC Connector assembly Table 2 Connector entry direction Note 1) AXT661 L LO M MO L-type plug connector, with lead
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) DAuto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 -X Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(1/4) 0.44 0.50 0.16 1/4-28UNF JM-025 6 (1/4) 0.31 0.36 0.11 6-40UNF JM-006 10 (3/8) JM-03 10 (3/8) 0.50 0.58 0.19 5/16-24UNF 0.38 0.43 0.13 10-32UNF JM-02 16 (5/8) 0.56 0.65 0.23 3/8-24UNF JM-04 16 (5/8) FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE N301
30 2 x 3.5 depth 1 4 x M4 x 0.7 depth 6 Variable angle (Female thread mounting) 90 19.5 1.9 (Power supply switch) 6 (With connector plugged in) 37.5 R41 (84) 25 R76 27 Fan Type Ionizer IZF10/IZF10R Series Dimensions IZF21/31 IZF10/IZF10R Technical Data Power supply cable IZF10-CP L 45 2 36 2 Terminal semi-stripped 3 1 7 1 4.3 4 1 Wiring/IZF10 Pin no.
2 n Auto switch model Different surfaces Same surface Different surfaces Same surface D-M9m 25 25 40 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mW 25 25 40 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mA 25 25 40 25 + 35 (n 2) 2 (n = 2, 4, 6)*1 60 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mV 25 25 35 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 35 + 35 (n 2)
E 03 05 07 09 't't 5132" 1l4', 5/16' 3t8" 1/2" 6mm 8mm H , T , U , X , N 1 3 06 08 t0 1 2 1 6 32 i10-32 UNF Thread 3 5 I l t N P r H ' L . W , r .
Barb fitting type (for rubber hose) Barb fitting type (for rubber hose) Model Hose nominal Model Hose nominal KK130P-07B -09B -11B -13B KK130S-07B -09B -11B -13B 6 (1/4") 6 (1/4") 8 (1/4") 8 (1/4") 9 (3/8") 9 (3/8") 12 (1/2") 12 (1/2") The figures in ( ) indicate the internal diameter of the applicable hose.
Winding direction Expose approx. 2 threads Pipe tape Class 1 Turbine Oil (with no additive), ISO VG32 3. Screwing in fitting When screwing fittings into valves, tighten as follows. 1) For M5 (1) When installing SMC fittings, etc., follow the procedures below. After tightening by hand, tighten an additional 1/6 rotation for M5 with a tool.