Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Entry on Left Side, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 1.5, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: No Cable, Controller Mounting: DIN Rail Mounting, DIN Rail not Included, Communication Plug Connector
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Entry on Left Side, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: No Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable
Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Entry on Left Side, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Mounting: DIN Rail Mounting, DIN Rail not Included, Communication Plug Connector or I/O
Size: 10, Motor Size: Compact Type, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Entry on Left Side, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Mounting: DIN Rail Mounting, DIN Rail not Included, Communication Plug Connector or
Size: 6, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 25mm, Motor Cable Mounting Direction: Entry on Left Side, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 3, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: No Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BA,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BW,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9PW, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BA,
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~1.0, Specification: Built-in magnet, Auto Switches: M9BA,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: M9BA, Lead