Nozzle Diameter: ø0.5, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: ø0.7, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Nil, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: None, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: ø0.7, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: ø1.0, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: ø1.0, Exhaust: 2 [Port Exhaust Rc(PT) 1/8], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: ø1.0, Exhaust: 2 [Port Exhaust Rc(PT) 1/8], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Mounting Style: -
Nozzle Diameter: 1.8 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: L Plug, w/o Lead Wire, Surge Suppressor: Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead Wire: For Switch D: Lead Wire
Nozzle Diameter: 2.0 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: L Plug, w/o Connector, Surge Suppressor: Light + Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead Wire: For Switch D:
Nozzle Diameter: 1.8 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3 m, Surge Suppressor: Light + Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead
Nozzle Diameter: 2.0 mm, Vacuum Pressure: -53 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3 m, Surge Suppressor: Light + Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead
Nozzle Diameter: 1.5 mm, Vacuum Pressure: -84 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3 m, Surge Suppressor: None, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead Wire: For Switch D:
Nozzle Diameter: 1.5 mm, Vacuum Pressure: -84 kPa, Exhaust: Port Exhaust, Valve: NO, Voltage: 24 VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3 m, Surge Suppressor: Light + Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead Wire: For
Nozzle Diameter: ø1.0, Body Style: Single Unit w/Valve + Standard Silencer, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: NPTF, Supply/Release Valve: Supply Valve+Release Valve, Solenoid Valve Rated Voltage: 3VDC, Electrical Entry: L Plug w/o Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking
Nozzle Diameter: ø0.5, Body Style: Single Unit w/Valve + Standard Silencer, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve+Release Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking
Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 3m, Port Size: -, Release
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
CE marking Precautions Caution D-A44C Relay, PLC 100 VAC 5 to 25 mA q Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. CE marking 24 VDC (3) 5 to 50 mA 200 VAC 5 to 12.5 mA 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2.
CQSX/CQ2X/CM2X 10 to 16 10 to 32 12 to 25 32 to 100 20 to 40 RE A B Air Cylinder Series CJ2X Page Minimum operating piston speed (mm/s) Bore size (mm) Minimum operating pressure (MPa) REC 10, 16 0.06 1 CX 10-3-6 CY MQQ M Free Mount Cylinder Series CUX Bore size (mm) Minimum operating pressure (MPa) Minimum operating piston speed (mm/s) RHC 10, 16 0.06 1 MK(2) 10-3-8 20, 25, 32 0.05 0.5 RS Q
B) In the state of A), attach the upper hard stop and adjust shim q so that there is a space of about 0 mm between the upper hard stop and the hard stop. During this step, theoretically, there is no clamping force applied to the hard stop. C) In order to generate a clamping force from the state described in step B), insert an additional shim.