For a facility with a large installation area that can vent the air naturally: Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility with a small installation area that can not vent the air naturally: Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
(Non-locking) 55.5 [62] 43.1 36.5 25.5 49 A A 19 9.5 21 (Pitch) n-Rc (PT)1/8 P=17 21 (A port) A A 19 9.5 18.5 (Pitch) n-M5 X 0.8 P=16 16 (A port) [ ] for AC Other dimensions are the same as the M5.
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 2 Cuts air consumption by operating the return stroke at a reduced pressure.
Relief valve 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester The micromesh element is a made to order specification (X0).
V +24 V for SI unit operation LED Description 8 Mounting hole Mounting hole for connection to the valve manifold SI0 V 0 V for SI unit operation 4 SF System fault 5 Unused Accessories BF BUS fault Hexagon socket head cap screw 2 pcs.
For example, when analogue output is 1 to 5 V, F.S.=5[V] 1[V]=4[V]. (Reference: 1%F.S. = 4[V] 1% = 0.04[V]) F F.S. (full span / full scale) Fluid contact part A part that comes into physical contact with the fluid. I Instantaneous flow The flow passing per unit of time. If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute.
Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the driver may cause a malfunction. 12. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. -6- (2) Using 1-phase 200 V AC to 240 V AC power supply for LECSN2-T Note 1. Between P3 and P4 is connected by default. 2.
IDX-OM-V020 Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA60-23-A,C,L,R,T,V IDFA70-23-A,C,L,R,T,V IDFA80-23-A,C,L,R,T,V IDFA90-23-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
Chapter 12 Option V Option V is a dryer with a timer controlled solenoid valve type auto drain.
Operating Conditions Model : ML2B32 Load : 15N Speed , Va : 0.25m/s Pressure : 0.5MPa L1 : 0.05m L2 : 0.05m W W L1 L1 Loading Static Loading Dynamic Loading A Load due to W W3 B Momentum due to W M2 C Momentum due to we when stopping M3 V D M1 V 2.
Evaporation thermometer V Dustproof filter provided as a standard accessory V All electrical components are located in the front of the product.
Designation Description Fieldbus interface connector (BUS IN) EtherNet/IPTM connection PORT 1 (M12 4-pin socket, D-coded) 4 2 SI24 V +24 V for SI unit operation 2 1 SV24 V +24 V for solenoid valve 2 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 4-pin plug, A-coded) 3 1 3 SI0 V 0 V for SI unit operation MS NS L/A1 L/A2 PWR(V) 4 Ground
Then, the charging time (T) for a 100 l tank, T = t x = 49 x = 49 (s). V 10 10 10 T = t x = 110 x = 110 (s). V 10 10 10 T = t x = 2.4 x = 24 (s).
W Dust proof Dust tight, Jet proof V V 1.11-5 Series VQ4000 Plug-in Conduit terminal 0 1 2 position single: VQ410 l 23.5 23.5 50 158 50 90 108 158 Indicator light 11 (A port) 11 (B port) (12.5) 5 3 (12.5) 9 4 2 38 48 10.5 1 11 A B 38 24.6 48 4 2 A 13.5 13.5 30 45 25.6 Mounting hole 14 5 1 3 12 30 45 25.6 Mounting hole 5-Rc1/4, 3/8 (R1, R2=Rc1/4) Manual override Bottom piping SMC (A, B port
NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire
B-1 A-1 B-2 A-2 B-3 A-3 Connector C terminal no. Signal Cable color S Standard cable Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
DC(+) 5 4 3 2 1 A DC(-) A DC(+) OUT1 OUT2 C DC(+) C DC(-) (FUNC) B DC(-) B DC(+) DC(-) NPN PNP -14NO.ZK2-OM00801-B NPN NPN 2 , 26.4 V 80 mA 2 V (NPN ) Assy (ZK2-LWA20-A) PNP PNP 2 , 80 mA2 V (PNP ) Assy (ZK2-LWB20-A) -15NO.ZK2-OM00801-B O O 2 ( :0.080.10 Nm) () -16NO.ZK2-OM00801-B 133 A 1 1 1 1 -17NO.ZK2-OM00801-B OUT1 (P_1)ON (P_1)(H_1)OFF P_1-70.0 kPa H_1:10.0 kPa OUT2
-wire(NPN) IC circuit Diagnosis (2-color indicator) 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA 3-wire(PNP) M9BAV M9BA 12 V 2-wire Auto switches marked with a symbol are produced upon receipt of order.
setting) 1 5 Output connector Output signal interface for valve manifold SI0 V 0 V for SI unit operation 4 0 1 1 6 LED and switch Bus statusspecific and SI unitspecific LEDs Unused 5 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.