The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting options, Standard with adjustable air cushion, Auto switch capable Auth/Grp: A/55. ME. ACTUATOR. NCA1 TIE-ROD CYLINDER. 410.

The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting options, Standard with adjustable air cushion, Auto switch capable Auth/Grp: A/55. ME. ACTUATOR. NCA1 TIE-ROD CYLINDER. 410.

Cartridge Single valve unit can be mounted anywhere. 2 port valve VCC12 3 port valve VCC13 M26x1.5 M26x1.5 23.8 23.8 45 55 Manifold Example 2 port valve and cleaning unit 3 port valve Cleaning solvent Paint 7 Circulating paint 5 Circulating paint 3 Circulating paint 1 PA IN PA IN PA RETURN RETURN RETURN IN PA IN PA IN R R R IN IN IN IN IN 100 80 80 120 OUT OUT IN IN IN IN IN R R R IN PA

Vacuum Pump, HP 1/2 hp, Displacement 1.2 cfm, End Vacuum 0.05 torr, NPT Inlet 3/8 in, Voltage 115, Amps AC 3, Overall Length 18 in, Overall Height 18 in, Overall Width 9 in, 60 Hz, 1 Phase, Weight 50 lb, Max. dBA 55, Application For Schlenk Line Drying Manifolds, Vacuum Ovens, Freeze Dryers Up to 6L, Centrifugal Concentrators

³ Noise Level, dBA 50 50 55 Motor Speed, RPM, @60Hz 1740 1740 1750 Motor Power, HP (kW) at 60 Hz 0.5 (0.4) 0.5 (0.4) 1.1 (0.85) Oil Capacity, L 1.15 1 2.4 Connection Flanges NW16 NW16 NW25 Inlet Hose Connection on -01 Models 5/8" to 3/4" 5/8" to 3

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C 4/5 PORT SOLENOID VALVE. 5 port pilot operated valve. 1250.00000 lb. I50.

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE/SOL, 4/5 PORT SOLENOID VALVE, 55 lb

Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE/SOL, 4/5 PORT SOLENOID VALVE, 55 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 1050 lb

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 55 lb

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 55 lb

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 55 lb

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 55 lb

Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 55 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 1100 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, 5 port pilot operated valve, 4/5 PORT SOLENOID VALVE, 1160 lb