Function: 1 (2 Position Single), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 1 (Direct Manual Override for Base Mounted Type), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 3 Input Blocks, Type of Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Model: 32, Orifice: 2 (2.2mm), Style: 4 (COM, Single Unit), Option: H (Stainless Steel, Seals: FKM, Class B), Suffix: Standard, Port Size: 02 (1/4), Thread: Rc, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Actuation: 1 (2-Position Single), Barrier: w/o Barrier, Electrical Entry: TT (Cable Type), Lead Wire Length: 100 [10000mm (semi-standard)], Manual Override: Non-Locking Push, Port Size: 02 (1/4), Thread Type: T (NPTF), Bracket: F2 (w/Side Bracket)
Function: 1 (2 Position Single), Body Style: 1 (Base Mounted Non Plug-in), Body Option: 0 (Standard for Base Mounted Type), Pilot: R (External Pilot), Voltage: 6 (12VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports
Actuation: 1 (2-Position Single), Barrier: w/o Barrier, Electrical Entry: TT (Cable Type), Lead Wire Length: 20 (2000mm), Manual Override: Non-Locking Push, Port Size: 02 (1/4), Thread Type: N (NPT)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Model: 32, Orifice: 4 (4mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: N (NPT), Voltage: 7 (240VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
A, B Port Size: 02 (1/4), Thread: F (G), Bracket: F (Bracket), Made to Order: X600 (TRIAC Output Specification)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: None, Semi-standard: RZ (Flow Direction: Right to Left + Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 3, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: B (w/Bracket), Semi-standard: RZ (Flow Direction: Right to Left + Name Plate & Pressure Gauge in Imperial Units: psi)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: W (M8 Connector w/ Connector), Lead Wire Length: 7 (5000mm), Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 02 (Base Mounted w/Sub-plate 1
Model: 33, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Body Size: 20, Back Flow: w/o Backflow, Thread: Rc, Port Size: 02 (1/4), Options: BG (B+G), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl: 2 (Metal Bowl), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa
Body Size: 40, Thread: Rc, Port: 02 (1/4), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: Y (Low Wattage Type), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 300mm), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4)
Series: 5 (VFA5000), Actuation: 1 (2 Position Single), Body: 20, A, B Port Size: 02 (1/4), Thread: Rc, Bracket: w/o Bracket, Pilot Port Direction: P (Lateral)
Stations: 11 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 02 (Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: D (D Side Mounting)
Model: 33, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: F (G), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)