Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
psig (1.0 MPa) 100 0.69 80 0.55 Delivery pressure (MPa) Delivery pressure (psig) 60 0.41 40 0.28 20 0.14 0 0.00 0 50 100 150 200 250 300 350 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.
WETTED MATERIALS Polysulfone, Silicone, Buna-N TEMPERATURE RANGE 40 150 F (4 66 C) REPEATABILITY < +/1% F.S.
How To Order Piston Rod Assembly Double Acting Single Rod NCA1 150 26A 0400 How To Order Cylinder Tube Double Acting Single Rod NC1A 150 04 0400 Bore 150 200 250 325 400 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Stroke (In Inches and Hundredths of Inches) *BLUE links will lead to purchase pages.
200 250 300 350 400 450 500 550 600 650 700 Flow rate (slpm, N2) AK1200HF 150 psig (1.0 MPa) 50 psig (0.34 MPa) Inlet pressure: 100 psig (0.69 MPa) AK1200FC Inlet pressure: 150 psig (1.0 MPa) 3/4 inch connections ) 100 0.69 75 0.52 0.62 90 0.55 80 60 0.41 Delivery pressure (MPa) Delivery pressure (MPa) Delivery pressure (psig) Delivery pressure (psig) 0.48 70 0.41 60 45 0.31 0.34 50 0.28
However under Japanese regulation, only MPa is available in Japan. 40 Specifications 1) Source pressure above 1000 psig (6.9 MPa) decreases maximum delivery pressure to less than 150 psig (1 MPa) due to supply pressure effect.
VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 Nozzle size Nozzle length 1.5 2 1.5 2 1.5 2 1.5 2 2.5 3 3.5 2.5 3 3.5 2.5
Mounting orientation Free Impact/Vibration resistance (m/s2) (2) 150/50 Note 1) Use turbine oil Class 1 (ISO VG32). Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve, each one time when pilot signal is ON and OFF .
Applicable Controller Power Supply Voltage 100VAC Specification Series LJ1H10 Series LJ1H20 LJ1H1021H-K (8mm lead) LJ1H2021F-K (5mm lead) 250 400 225 350 12kg 6kg 200 300 175 250 Speed (mm/s) Speed (mm/s) 150 8kg 13kg 125 200 10kg 100 150 14kg 75 100 15kg 50 50 25 0 100 200 Stroke (mm) 300 400 0 100 200 300 400 500 600 Stroke (mm) When an actuator is operated under conditions that exceed
F A A Lr Lr = 200mm L X S 400 8 60 Table displacement (m) LXSH-150 Table displacement (m) Table displacement (m) 350 7 LXSH-150 LXSH-150 50 300 6 LXSH-125 LXSH-125 250 5 40 LXSH-125 LXSH-100 LXSH-100 200 4 30 LXSH-75 LXSH-100 LXSH-75 3 150 20 LXSH-50 LXSH-75 2 100 LXSH-50 LXSH-50 10 1 50 1 2 3 4 5 6 8 9 7 0 0 0 1 2 3 4 5 6 8 9 10 10 10 7 1 2 3 4 5 6 8 9 7 Weight (kg) Weight (kg) Weight (kg
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com