Actuator: LJ1H3031A-K Work piece load: 9kg Speed: 300mm/s Stroke: 500mm 250 200 10kg 150 12kg 14kg 16kg 1 8kg 20kg When the above conditions are used, mark a position based on the speed and stroke.
How to order manifold VV5Q13 1(P), 3(R) port size: 1/4 08FSO DN 00T P How to order valves VQC VQ1130 5 N7 Cylinder ports Example) VV5Q13-09FS0-D K S SQ Applicable tube O.D. (Inch) 1/8" 5/32" 1/4" N1 N3 N7 Symbol VQ0 DIN Rail Mounting Others, option symbols: to be indicated alphabetically. VQ4 Each manifold can be mounted on a DIN rail.
color 76 41.5 29.5 12 3.2 12 14.2 L type: Black color 76 41.5 29.5 12 3.2 12 14.2 1 8 82 44.5 30.5 12 4.2 12 17.2 86 44.5 30.5 12 4.2 12 17.2 94.5 54 39 14 4.2 17 19.95 99.5 54 39 14 4.2 17 19.95 116.5 58.5 41 17 4.2 19 ZH15DS-02-03-03 22.45 116.5 58.5 41 17 4.2 19 ZH15DL-02-03-03 22.45 (Mounting hole) Model I J K L M N O P Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc 1 8 Rc
o n ti ti e g a n o a r ti a a e t n 1 t t o o g o 0 1 r e Key r r 0 9 y 2 y y 0 e 8 e e +4 0 K 0 K K +4 0 +4 0 +4 0 0 Key Key 0 (40) 1 Key e g n a r n o ti a t o r y (85) e (40) K (40) A port B port A port B port A port B port A port B port 4 Series CRB1 With Auto Switches Applicable auto switches Auto switch model Electrical entry Indicator light (lights when ON) Yes D-R73 Grommet
IDFA 100 F 40 C G K 100 125 150 ) 100kW 125kW 150kW ) R V 38 AC380V(50Hz) 40 AC400V(50Hz) C G K R V IDFA100F150F 1 1 1.1 IDX-OM-U022 1. 1.2 1.2.1 (C) 1.2.2 G . 1.2.3 K 1.6MPa 1.2.4 R 30A (IDFA100F, IDFA125F, IDFA150F) 30mA 1.2.5 V ON 1.5 OFF 0.5 IDFA100F150F 1 2 1.2 IDX-OM-U022 1. 1.3 A 3 A IDFA100F150F 1 3 1.3 IDX-OM-U022 1.
k 600 IP67 -34No.EX-OMN0037CN-A 0V 2 EX600 4 (-)2 (+) 4 3 4 -35No.EX-OMN0037CN-A LED LED OFF OFF 0 1 () () (SI ) -36No.EX-OMN0037CN-A EX600-AMB M12 (5 ) 1 2 (1 /) () DC24 V Class22 A 0.5 A/ 12 bit 010 V15 V05 V 020 mA420 mA 15 V 40 mA 100 k 250 (25 ) 0.05 F.S. (25 ) 0.15 F.S. (25 ) 0.5F.S. 0.6F.S.
24 66 to 400 104 110 LJ1H102NH-K 28 70 to 400 LJ1H202PA-K 34 76 to 500 106 112 LJ1H202NA-K 38 80 to 500 LJ1H102PB-K 26 68 to 600 145 104 110 LJ1H102NB-K 30 72 to 600 LJ1H202PF-K 32 74 to 250 106 112 LJ1H202NF-K 36 78 to 250 LJ1H303PA-K 40 82 to 500 108 114 LJ1H303NA-K 42 84 to 500 Page Standard stroke (mm) and Speed (mm/s) Nonstandard motor Model Standard motor Deflection 100 200 300
200W With brake Nil 1 2 3 4 5 6 7 A B Without switch and switch rail Photo micro sensor 1 pc., Photo micro sensor rail 1 pc.
1 B N 3 Mounting bracket Number of axes 1 3 5 M3 M5 1 axis Actuator Classification Mounting Note 1) Series LJ1 (incremental) B N: T-nut mounting L: T-bracket mounting Adaptable actuators Compatible actuator models Symbol Motor capacity 50W 1H LJ1H101B LJ1H202A LJ1H202C LJ1H303D LJ1S101SC LJ1S202SC LJ1S303SE LJ1H101SC LJ1H202SC LJ1H303SC LJ1H102H-K LJ1H102B-K LJ1H202F-K LJ1H202A-K LJ1H303A-K
k 1 k Load OUT1 (Black) OUT2 (White) 12 to 24 VDC 12 to 24 VDC Load Load DC () (Blue) DC () (Blue) ZSE40(F) ISE40--30(L)-(M) With auto shift input ZSE40(F) ISE40--70(L)-(M) With auto shift input DC (+) (Brown) Auto shift input (Gray) OUT1 (Black) OUT2 (White) DC (+) (Brown) Auto shift input (Gray) 1.2 k 1.2 k Load 6.8 k 6.8 k Main circuit Main circuit Load OUT1 (Black) OUT2 (White) 12 to
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, 1/4-28UNF, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant