The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BODY PT
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV30003/81.5 MPa0.2 to 1 MPa1/80 to 60C (1)37490.48100, 200, 110
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, BASE MT
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
The VQ20/30s long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110,
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VQZ3000 BODY PORT (1/4 PT),
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air, Cv factor: 0.008 standard style; 0.012 large flow capacity style, Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC, Response time: 10ms or less, Cycle life: 100 million cycles (by SMC life test), Ambient and fluid temperature: max. 50C, VALVE, SOL, VALVE,
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT,COMPACT (DC
The SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BASE MOUNT (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50 C, VALVE, BASE MOUNT, DIN (DC), VALVE
The VQ20/30s long life, high speed coil (up to 20 million cycles at 100cps for pneumatic use) along with its all plastic construction, make it an excellent choice for those who want high performance at a lower cost.Fluid: Air/inert gas, Operating pressure range: 0.01-0.6MPa, Effective area (Cv/effective orifice): 7.2mm 2 -17.5mm 2 (0.4/ 3-1/ 4.8), Coil rated voltage: 12, 24VDC; 100, 110,
pressure rangePressure gauge port sizeAmbient and fluid temperatureEffective area (mm2)Mass (kg)Electrical specificationsPilot valve manual override1(P) 2(A)2(A) 3(R)Rated coil voltageAllowable voltage fluctuationCoil insulation typeApparent power AC(Current consumption)Current consumption DCElectrical entryOption specificationsAV30003/81.5 MPa0.2 to 1 MPa1/80 to 60C (1)37490.48100, 200, 110