Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: YO (DIN EN175301-803 Terminal w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: F (G)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 03 (3/8), Thread: F (G)
Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), Port Size: 03 (3/8), Thread: T (NPTF)
Series: 2 (10-SV2000), Enclosure: W10CD, Valve Stations: 03 (3 Stations), P, E Port Locations: U (U Side, 2-10 Stations), SUP/EXH Block Assembly Specifications: Internal Pilot, A, B Port Size: N3 (One-touch Fitting for Ø5/32)
For example, the element type used with an “FGDCA-03-B002N-B” is the “EB100-002N.” For details, refer to the respective catalogs.
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: Y [DIN Terminal w/Connector (DIN 43650C)], Lead Wire Length: None, Surge Suppressor: None, Manual Override: E (Push-turn Locking Manual Override), A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: F (G)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: R (External Pilot), Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: N (NPT)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: N (NPT)
Model: LVH30 (Body Class 3, N.C.), Lever Operation: Non-locking, Self-reset, Port Size: 03 (3/8), Pilot Port Thread: N (NPT), Material: B (Body: PPS, Actuator Section: PP, Endplate: PPS, Diaphragm: PTFE)
Body Size: 3, Set Pressure: 0 (0.02 to 0.2 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 03 (3/8), Option: BG (B + G), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 3, Set Pressure: 2 (0.02 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 03 (3/8), Option: BG (B + G), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 3, Set Pressure: 2 (0.02 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 03 (3/8), Option: B (w/Bracket), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 3, Set Pressure: 2 (0.02 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 03 (3/8), Option: B (w/Bracket), Semi-standard: None
Body Size: 3, Set Pressure: 2 (0.02 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 03 (3/8), Option: BG (B + G), Semi-standard: None
Body Size: 3, Set Pressure: 0 (0.02 to 0.2 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 03 (3/8), Option: B (w/Bracket), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
/Single Unit), Solenoid Valve Option: Brass Body, NBR Seal, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread Type: Rc, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Full-wave Rectifier: R (w/Full-wave Rectifier)
/Single Unit), Solenoid Valve Option: Brass Body, NBR Seal, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread Type: Rc, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: DZ (DIN Terminal w/Surge Voltage Suppressor and Light), Full-wave Rectifier: None