C D E F G H J K L AS100P-04-04 AS200P-04-04 AS200P-06-06 AS250P-06-06 AS300P-08-08 AS300P-10-10 23.9 31.4 31.3 33.6 37 37.5 41.7 51.4 52.3 54.6 60.5 63.5 26.7 36.4 36.3 38.6 42 42.5 38.9 46.4 47.3 49.6 55.5 58.5 26 30 30 32 36 39 9.3 9.3 11.6 12.8 15.2 18.5 17 17.1 18 18 19 22 4 4 6 6 8 10 4 4 6 6 8 10 10 13.6 13.6 17 22 22 12.7 12.7 13.5 16.8 18.5 21 17.4 18.9 19.9 24.1 27 30.5 22.4 25.7
AS3001F-07-3 1/4" 13.2 59 7.4 31.3 60.1 54.7 17 100 84 12 20.9 AS4001F-10-3 77.7 AS3001F-09-3 82.1 11.3 35 69.3 61 21 5/16" 21 15.2 32.1 3.5 60.9 55.5 18 64.4 8.2 167 88 18.5 16 10 18.5 27 21 24.5 3.5 AS4001F-12-3 36 70.3 62 22 AS3001F-11-3 3/8" 17.2 33.3 62.1 56.7 21 70.8 9.5 171 95 12 20.9 Note 1) Reference dimensions AS4001F-11-3 3/8" 27 21 17.9 34.9 3.5 69.2 60.9 21 76.9 10.3 175 24.5
6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AM AFF2B 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253
O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AMH150 1 8 1 4 3 8 166 187 187 218 218 241 241 277 334 24 27 27 32 32 37 37 39 55 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122
O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 45 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AFF 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24 27 27 32
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
N101 Exhaust Cleaner for Clean Rooms AMPSeries Exhaust Air Cleanliness Equivalent to Class 100 Piping Labor Reduced Increased Space Savings Worry Free Two Stage Element Construction Series AMP Exhaust Cleaner for Clean Rooms An exhaust cleaner that can be used inside a clean room Exhaust air cleanliness: Equivalent to Class 100 (Consult SMC in advance, as this will differ depending on the
NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
PLC H.T. ) Enable (SC_MonSs) 1 Disable Enable 2 1 2 (OC_Mon) Disable Enable (Inrush) 100msec 3 Disable 0.1 ms 1.0 ms 4 (Filter_T) 1.0 ms 10 ms 20 ms 1.0 ms 15 ms 5 (SigExt_T) 15 ms 100 ms 200 ms Enable Val165000 4 ON 3 ON/OFF (Counter) 6 Disable 1(EX600-DXPC1EX600-DXNC1) 22 OFF 0.5 mA ()OFF 0.5 mA 3 OFF 0.5 mA 31 4x1000 -54No.EX-OMN0027CN-D No. (H.T.
SI unit for SV series valves ( EX500-S 01 ) ( EX500-Q 02 ) PWR PWR COM COM 64.4 80.3 64.4 28 66 84.8 79.4 68.5 80.3 series 54.5 60 60 43.2 43 43.2 22.2 22 22.2 13 10.5 28.6 44 0 1 36 10.5 1 0 22 23 The mounting and removing methods of SI unit are as shown below.
Connection thread size Proper tightening torque (Nm) M R 1/8 7 to 9 R 1/4 12 to 14 H/DL L/LL R 3/8 22 to 24 R 1/2 28 to 30 KC Installation of Threads 3. Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads.
(mm) Electrical entry P Port size A B C D E F H K L M Model Grommet: G Conduit: C DIN connector: D Conduit terminal: T Q R Q R Q R S Q R S 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 22 45 44 43 58 40.5 46.5 99 43 66 1/8 VCW21 18 36 67 31 8.5 12.5 28 18 12.8 M4 22 46 44 44 58 41.5 46.5 99 44 66 1/4 22 40 80.5 36.5 11 15 32 20 19 M5 24 56.5 46 54.5 60 52 48.5 101 54.5 68 1/4, 3/8 VCW31 30 50 85.5
IN side, OUT side 4 10 20 30 50 75 75 Weight (g) 22 22 30 30 39 39 Model Tubing size ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 7 7 12 12 16 16 Unrestricted 360 piping tube mounting on the IN side 6 6 8 8 10 Metric size Easily replaced filter element Easy installation and removal with One-touch fittings ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 22 22 30 40 62 20 20
M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5 34.5 M52 x 1.5 34.5 42.5 72 42.5 72 50 38 54 8.5 26.5 70
Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B B A W A B stroke 6 5 to 30 3.5 0 17 6.5 13 3.5 2.5(5) 17 4.5 5 to 20 17 13 17 10 25 7.5 3.5 20 16 2.5 7.5 20 1.5 0.5 30 19 15 19 (1) 5 27 23 27 10 22 18 22 15 27 23 27 16 8 4 2 8 2 0 B A 20 22 18 22 Bore (mm) 6 10 16 25 27 23 27 (0.5) 6.9 10 30 27 23 27 8.8 14 13.9 19 Note 1) Negative figures
Use the series AKM check valve to avoid such possibility. 57 53 30 81 22 Notes) in model numbers indicates a thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit.
Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B A B B W A stroke 6 5 to 30 0 13 3.5 3.5 6.5 17 2.5(5) 17 4.5 5 to 20 13 17 17 10 25 3.5 16 7.5 7.5 2.5 20 1.5 20 0.5 30 15 19 (1) 19 5 23 27 27 10 18 22 22 15 23 27 27 16 4 8 8 2 2 0 A B 20 18 22 22 Bore (mm) 6 10 16 25 23 27 27 (0.5) 10 6.9 30 23 27 27 14 8.8 19 13.9 Note 1) Negative figures
S) (mm) Dimensions PB S Model LVD2-T LVD3-T LVD4-T LVD5-T PA 13 26 A B 26 29.5 Dimensions (mm) A B C D E F G H J K L M N P Q T U Model LVD2-T LVD3-T LVD4-T LVD5-T 30 30 61 56 14.5 104 35 13 4 20 44 7 30 6 31.5 17 M5 to 0.8 35 35 79.5 62 17.5 136 42.5 17.5 6 22 50 7 37 6 36 21 M5 to 0.8 35 35 82 62 20 137 45 17.5 6 22 50 7 39 6 36 21 M5 to 0.8 45 45 105.5 76 25 169.5 65 17.5 8 32 64 7 52 6