SMC Corporation of America
Elite Part Number Search
Search Results "22-MXQ25-150-M9PW"

To booster lube From booster lube To booster lube From booster lube A B 63 63 80 85 90 100 C Port size Rc INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model 1 4 3 8 15 15 15 20 22 22 141 164.5 170 180 230 251 , , 1 4 3 8 1 2 B C D E F Port size Rc Part no. A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket (Option) B C A INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model Port size Rc 4 1 63 63 80 85 90 100 141 164.5 170 180 230 251 15 15 15 20 22 22 8 3 , , 8 3 4 1 2 1 Bracket dimensions E D C B A Model Port size 4 3 F 345 419.2

Range Back Pressure SMC 22 8.0 -750mmHg~58psi 0~100C 0~30psi (60psi) 136 150 75 Height Width Operator Dia. 1 LVQ60 LQ Seal Locations N u t S e a l L o c k T ubing Support T aper Surface T u b i n g T r ap e zoidal T h re a d s I n s e rt Bushing Nut Lock U.S. Patent #5,996,636 Quadruple Seal Maximum leak protection. Up to 215psi @ 200C.

Rubber seal 10.8 (0.6) VQZ242 20 or less 15 or less Metal seal 14.4 (0.8) VQZ312 22 or less 17 or less N.C. Rubber seal 16.2 (0.9) VQZ332 33 or less 25 or less 92 VQZ300 Metal seal 13.5 (0.75) VQZ322 22 or less 17 or less N.O.

P 500 150 144 400 104 100 300 P 66 43 26 16 90 200 50 56 34 22 14 8 5 100 0 0 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 10 Bore size (mm) Bore size (mm) 1.15-33 Series VY511/VYU5 Precautions Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instruction and common precautions on the products mentioned in this catalog.

I @$ttr SERIES NCJ2 Standard Type: Double Acting/Double Rod Series NCJ2W Bore Size s6, a1O, a16 NCJ2W Special options ffi:Htsh t".p"r.t*" typ" ffi'L"r t"mperat,"e tvpe See page 22 lor specilicalions of spocial options.

Accessory (Option) Tank capacity ID D With auto-drain F Companion flange Port size Capacity ( l ) 100 200 400 500 700 1000 1500 Applicable compressor (kW) 5.5 Symbol AMG 6C 04 Rc 06 14 20 30 1 2 Rc 3 4 Rc 1 1 2 2B flange 3B flange 40 4B flange AT6C AT11C AT22C/37C AT55C/75C AT125C AT150C/220C 11C 11 22C 22 AFF 37C 37 55C 55 AM 75C 75 125C 125 2000 150C 150 3000 220C 220 Misc. 14-16-1 2 Series

Standard stroke -X Bore size (mm) Standard stroke (mm) Piping port location 15, 32 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700 Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left Operating direction: Right Operating direction: Left a b c d e f g h 20Nil Note 1) Please consult

NG Nominal thread size Proper tightening torque [Nm] Rc (NPT) 3/8 22 to 24 Rc (NPT) 1/2 28 to 30 Rc (NPT) 3/4 28 to 30 Rc (NPT) 1 36 to 38 NG Off-centering 6. When using a One-touch fitting, hold the fitting by hand to prevent the load required for connecting or disconnecting the tube from being imposed directly on the product. 2. The product body is made of resin.

IDF-S0535 1 H24.2 x W21.9 (H614 x W556) For IDFB80, IDFB90 Bowl assembly 5 B Refrigerated Air Dryer IDFB Series Standard Specifications Model Specifications IDFB60 -11 IDFB60 -23 IDFB70 -23 IDFB80 -23 IDFB90 -23 Fluid Compressed air Inlet air temperature [F (C)] 41 to 149 (5 to 65) Inlet air pressure [psi (MPa)] 22 to 150 (0.15 to 1.0)8 Operating range1 Ambient temperature (Humidity) [F (

Enable 1 Disable Enable 1 2 2 Disable Enable 100 msec 3 Disable 0.1 ms 1.0 ms 4 1.0 ms 10 ms 20 ms 1.0 ms 15 ms 5 15 ms 100 ms 200 ms Enable Val165000 4 ON/OFF ON/OFF 6 3 Disable ON/OFF 0 83 ON/OFF 7 1(EX600-DXPC1EX600-DXNC1) 22 OFF 0.5 mA ()OFF 0.5 mA 3 OFF 0.5 mA 3 4x1000 -45No.EX-OMS0026CN No.

(mm 0.81.0 ZS-28-C 24-26 0.14-0.2 1.01.2 ZS-28-C-1 1.21.6 ZS-28-C-2 23 0.1-0.5 1.151.35 ZS-28-CA-4 1.01.2 ZS-28-C-3 20-22 0.3-0.5 1.21.6 ZS-28-C-4 1.62.0 ZS-28-C-5 SMC 3M ZS-28-C 37104-3101-000FL 1-1473562-4 ZS-28-C-1 37104-3122-000FL ZS-28-C-2 37104-3163-000FL ZS-28-CA-4 2-1473562-4 ZS-28-C-3 37104-3124-000FL ZS-28-C-4 37104-3165-000FL ZS-28-C-5 37104-2206-000FL -12No.PS-OMG0001CN-H

/ mm mm mm c.p.m. mm(L1-L2) (L1) (L2) g MHL2-10D 60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D

L dimension 19 248 18 235.5 17 223 16 210.5 15 198 14 185.5 13 173 12 160.5 11 148 No. 20 260.5 L dimension 30 385.5 29 373 28 360.5 27 348 26 335.5 25 323 24 310.5 23 298 22 285.5 21 273 No. Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

06 6kgticnf 11 30psi 12 45 psa 13 150 psi 22 23 24 26 41 I t al (Silicon) Low Temperatufe L Porl Connection NIL PT Thr6ad PF Parallel Pip Thread t l{PT Amarican National Standard Pioe Thread Acceesoris t l{ll Standard Lever Control Lengrth (0.25 to 3.35 inches) (6lo 85mm) D High Pressure Signal Spring K 1/2 Split Range Spring E Longsr Lever Control Length (2.35 to 4.33 inchss) (60 lo 11omm

The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (50 kPa) when the product is set to turn ON at 150 kPa supply pressure. Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa).

DIN / ON/OFF() ON () -14No.PS-OMT0001CN-E 2 (ISA3) ISA3-F ISA3-G ISA3-H (5 m ) 0.010.03 mm 0.020.15 mm 0.050.30 mm () 1 060 2 10300 2 30500 2 () 1 1 100200 kPa OUT1 OUT2 5 () 3 -20220 kPa 0.005 mm 0.010 mm 0.020 mm (25 ) 0.010 mm 0.015 mm 0.030 mm 0 0 (3) (20) 0200 kPa -20220 kPa / 1 kPa OUT2 6 0.5F.S. 1 digit (25 ) 2F.S. 0 7 600 kPa 1.5 4 5 L/min 12 L/min 22

25 to 70C (with no freezing and condensation)Operating, Stored: 35 to 85%RH (with no condensation)1000 VAC for 1 min. between whole charging part and case2 M or more (500 VDC Mega) between whole charging part and case10 to 150 Hz with a 0.7 mm amplitude or 50 m/s2 in each X, Y, Z direction for 2 hrs (De-energized)150 m/s2 in each X, Y, Z direction, 3 times (De-energized)CE marking, UL (CSA

0.25 to 0.7 MPa (Same as operating pressure) Maximum operating frequency 30 times/minute Minimum operating frequency 1 time/week Operating and ambient temperature 14 to 122F [10 to 50C] (No freezing) Ambient humidity 20 to 90%RH (No condensation) Manual override None Pilot exhaust Individual exhaust Lubrication Not required Mounting orientation Unrestricted Impact/Vibration resistance 150

Depending on the model, flow capacities are available from 150 to 16100 CFM.