Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: AT (Integrated Display; Out 1: NPN; Out 2: (NPN) ⇔ NPN ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None,
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L;
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate NPN; Temperature: NPN; w/Temperature Sensor), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °C)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment), Port Size: 04 (TSJ1/2, Compression Fitting), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate NPN; Temperature: NPN; w/Temperature Sensor), Lead Wire: with Lead Wire with M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min; Accumulated Flow: gal; Temperature: °F)
Speed may be accurately controlled even at low speeds. Able to control and set a constant speed easily. Retainer prevents accidental loss of needle.
AS431F-04 R 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated by the lock nut.
Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.
How to Order Caution on Design HA AT 22C 14 Caution AT 1. Use outside Japan is not allowed. The AT series air tank is in compliance with the regulations in Japan (Class 2 Pressure Vessel), but is not in compliance with related regulations outside Japan. Please consult with SMC for use of air tanks outside Japan. 2. Use a pressure gauge below 50C.
mounting hole (with the cover at socket side) Panel mounting hole DM12 Panel mounting hole (with the cover at socket side) Panel mounting hole A B Part No.
L M50.8 3.0 8 LEYG16 4 M L M61.0 5.2 11 LEYG25 / M L M61.0 5.2 12 LEYG32 [Nm] L[mm] M L M40.7 1.5 32 LEYG16 L M L M50.8 3.0 40.5 LEYG25 M L M50.8 3.0 50.5 LEYG32 / [Nm] [mm] M L M50.8 3.0 10 LEYG16 M L M61.0 5.2 12 LEYG25 M L M61.0 5.2 12 LEYG32 / [Nm] [mm] M L M40.7 1.5 7 LEYG16 M L M50.8 3.0 8 LEYG25 M L M61.0 5.2 10 LEYG32 LEY / 0.1mm / 0.05mm LEYG / 0.05mm 7.4. -45- 6 /250km /500
ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE
The screw on the topmost section is a zero point adjustment screw which is locked at the factory and requires no adjustment for operation. 1. Do not use a precision regulator outside the range of its specifications as this can cause failure. (Refer to specifications.) 2.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.01609 lb
All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing. However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.
Number of needle rotations has been increased (8 to 10 turns) The increased number of needle rotations (8 to 10 turns) permits easy control at low speeds.
(Note 1) According to this formula, multiply the following values by the piping length (□m) to get the piping resistance.
Approx. 0.0035 MPa/m for a port size 15A thermo-chiller (Note 2), approx. 0.0026 MPa/m for a port size 20A thermo-chiller (Note 2), and approx. 0.0022 MPa/m for a port size 25A thermo-chiller (Note 2). However, SMC does not design or install piping systems.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)